background image

American DJ

®

  -  www.americandj.com  - X-Scan LED Plus Instruction Manual Page 6

American DJ

®

  -  www.americandj.com  - X-Scan LED Plus Instruction Manual Page 5

Power Supply:

 The American DJ

®

 X-Scan LED

 

Plus contains an elec-

tronic ballast, which will auto sense the voltage when it is plugged into 
the power source. With the electronic ballast you do not need to worry 
about wall voltage, this unit can be plugged in anywhere. Also be sure 
to only use the included I.E.C. power cable supplied with the unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 
communication  between  intelligent  fixtures  and  controllers. 

A  DMX 

controller sends DMX data instructions from the controller to the fix

-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX  Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of  different  manufactures  to  be  linked  together  and  operate  from  a 

single  controller,  as  long  as  all  fixtures  and  the  controller  are  DMX 

compliant.

  To  ensure  proper  DMX  data  transmission,  when  using 

several DMX fixtures try to use the shortest cable path possible. The 
order in which fixtures are connected in a DMX line does not influence 
the DMX addressing. For example; a fixture assigned a DMX address 
of 1 may be placed anywhere in a DMX line, at the beginning, at the 
end, or anywhere in the middle. Therefore, the first fixture controlled 
by the controller could be the last fixture in the chain. When a fixture 
is  assigned  a  DMX  address  of  1,  the  DMX  controller  knows  to  send 
DATA assigned to address 1 to that unit, no matter where it is located 
in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The X-Scan LED Plus can be controlled via DMX-512 pro-

tocol. The X-Scan LED Plus is be a eight channel 
DMX  unit.  The  DMX  address  is  set  electronically 
using the controls on the rear panel of the unit. Your 
unit  and  your  DMX  controller  require  a  approved 
DMX-512 110 Ohm Data cable for data input and 
data output (Figure 1). We recommend Accu-Cable 
DMX cables. If you are making your own cables, be 
sure to use standard 110-120 Ohm shielded cable 
(This cable may be purchased at almost all profes-
sional  sound  and  lighting  stores).  Your  cables  should  be  made  with 

 X-Scan LED Plus   

                                           Set Up

Figure 1

a  male  and  female  XLR  connector  on  either  end  of  the  cable.  Also 
remember that DMX cable must be daisy chained and cannot be split.

 X-Scan LED Plus   

 

 

                       Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Summary of Contents for X-Scan LED Plus

Page 1: ...pport first Introduction The X Scan LED Plus is a eight channel DMX intel ligent LED scanner The X Scan LED Plus can operate as a stand alone fixture or in a Master Slave configuration The X Scan LED Plus has two operating modes sound active mode and DMX control For best results use fog or special effects smoke to enhance the beams projections Customer Support American DJ provides a toll free cust...

Page 2: ...into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance X Scan LED Plus Safety Precautions American DJ www americandj com X Scan LED Plus Instruction Manual Page 4 American DJ www americandj com X Scan LED Plus Instruction Manual Page 3 DMX 512 Protocol Compatible Eight DMX Channels X Y Mirr...

Page 3: ... your DMX controller require a approved DMX 512 110 Ohm Data cable for data input and data output Figure 1 We recommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all profes sional sound and lighting stores Your cables should be made with X Scan LED Plus Set Up Figure 1 a male and female XLR conne...

Page 4: ... a 3 pin DMX line When inserting stan dard 5 pin data cables in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a proper cable conversion Conductor 5 Pin XLR Male In 3 Pin XLR Female Out Pin 1 Pin 5 Do Not Use Pin 4 Do Not Use Pin 3 Pin 2 Pin 1 Pin 3 Pin 2 Not Used Not Used Data True signal Data Compliment signal Gro...

Page 5: ...ON or OFF Press the UP or DOWN buttons to select ON to activate sound active mode or OFF to deactivate sound active mode 3 Press ENTER to confirm BLND Blackout or Stand by mode 1 Tap the MENU button until BLND is displayed press ENTER Either Yes or No will be displayed 2 To activate Blackout tap the UP or DOWN buttons until Yes is displayed press ENTER to confim The fixture will now be in Blackout...

Page 6: ...TER button 3 On the slave units tap the MENU button until SLMD is dis played and Press ENTER 4 The slave units will now follow the Master unit Universal DMX Control This function allows you to use a Elation universal DMX 512 controller to control the chases and patterns dimmer and strobe A DMX controller allows you to create unique programs tailored to your individual needs 1 The X Scan LED Plus i...

Page 7: ...s ENTER 3 The optional UC3 Controller not included may be used to con trol different functions including blackout X Scan LED Plus UC3 Control The optional UC3 Controller not included may be used to con trol different functions including blackout Stand By Blackout the unit Function 1 Sync Strobe 2 A sync strobe 3 Sound Strobe 1 Select Gobo 2 Select Color Mode Sound LED OFF LED On X Scan LED Plus DM...

Page 8: ... to wipe down the cooling vents and fan grill 3 Clean the external optics and mirror with glass cleaner and a soft cloth every 20 days 4 Clean the internal optics with glass cleaner and a soft cloth every 30 60 days 5 Always be sure to dry all parts completely before plugging the unit back in X Scan LED Plus DMX Traits Channel Value Function 5 SHUTTER STROBE 0 7 BLACKOUT 8 15 SHUTTER OPEN 16 131 S...

Page 9: ...ce and repair labor by reason of defects in material or workmanship The sole responsibility of American DJ Inc under this warranty shall be limited to the repair of the product or replace ment thereof including parts at the sole discretion of American DJ All products covered by this warranty were manufactured after January 1 1990 and bear identifying marks to that effect E American DJ Inc reserves...

Page 10: ...nd Active Yes Working Position Any Safe Secure Position Warranty 3 Year 1095 days American DJ www americandj com X Scan LED Plus Instruction Manual Page 19 Auto Sensing Voltage This fixture contains a electronic bal last which will auto sense the voltage when it is plugged into the power source American DJ American DJ World Headquarters 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 323 582 2650 ...

Reviews: