Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

Tempest 575H.™ The American DJ

®

 Tempest 575H

 is available in a 

120v and 220v version. Because line voltage may vary from venue to 
venue, you should be sure your unit voltages matches the wall outlet 
voltage before attempting to operate you fixture.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. 

A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-
gle controller, as long as all fixtures and the controller are DMX com-
pliant.

 To ensure proper DMX data transmission, when using several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Dipswitches in DMX mode:

 This unit uses dipswitches to assign a 

DMX address. Each dipswitch represents a binary value. 
Dipswitch 1 address equals 1 

 

Dipswitch  2 address equals 2 

 

Dipswitch  3 address equals 4 

 

Dipswitch  4 address equals 8 
Dipswitch  5 address equals 16 

 

Dipswitch  6 address equals 32
Dipswitch  7 address equals 64 

 

Dipswitch  8 address equals 128
Dipswitch  9 address equals 254

Dipswitch  10  -  Some  units  omit  dipswitch  10.  When  a  unit  does 
include dipswitch #10, it is usually used for special functions such as 

 Tempest 575H™   

 

 

                       Set Up

ON

1

9

8

7

6

5

4

3

2

10

128

2

8     32  

256

65

16

4

1

SF

DMX CHANNEL

sound activation.

Assigning  DMX  Address: 

Each  dipswitch  has  a  preset  value.  A 

specific DMX address is set by combining the dipswitches that sum 
your  desired  value.  For  example:  To  achieve  a  DMX  address  of  21, 
combine dipswitches 1, 3, and 5. Since dipswitch 1 has a value of 1, 
dipswitch 3 has a value of 4, and dipswitch 5 has a value of 16, the 
combination of the three create a DMX value of 21.

Set DMX address 21:         

Set DMX address 201:

Dip-switches #   1 = 1            

 

Dip-switches #   1 = 1

 

 

3 = 4 

 

 

 

             4 = 8

 

 

5 = 16   

             

             7 = 64

 

 

   = 21   

             

       

8 = 128

   

 

      

 

 

 

 

   =  201

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The  Tempest  575H™  can  be  controlled  via  DMX-512 

protocol. The Tempest 575H™ is a one channel DMX unit. The DMX 
address is set on the side panel of the Tempest 575H.™ Your unit and 
your DMX controller require a standard 3-pin XLR 
connector  for  data  input  and  data  output  (Figure 
1). If you are making your own cables, be sure to 
use standard two conductor shielded cable (This 
cable may be purchased at almost all pro sound 
and lighting stores). Your cables should be made 
with a male and female XLR connector on either 
end of the cable. Also remember that DMX cable 
must be daisy chained and can not be split.

Figure 1

 Tempest 575H™   

 

 

                       Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Summary of Contents for Tempest 575H

Page 1: ...r any comments or suggestions Service Hours are Monday through Friday 9 00 a m to 5 00 p m Paci c Standard Time Voice 800 322 6337 Fax 323 582 2610 E mail support americandj com To purchase parts onli...

Page 2: ...e this unit rain or moisture Do not spill water or other liquids into or on to your unit Be sure that the local power outlet match that of the required volt age for your unit Do not attempt to operate...

Page 3: ...Dipswitch 7 address equals 64 Dipswitch 8 address equals 128 Dipswitch 9 address equals 254 Dipswitch 10 Some units omit dipswitch 10 When a unit does include dipswitch 10 it is usually used for speci...

Page 4: ...ata Compliment signal Ground Shield 3 Pin XLR to 5 Pin XLR Conversion Operating Modes Universal DMX Control This mode allows you to use a universal DMX 512 controller such as the American DJ DMX Opera...

Page 5: ...nment in which the fixture operates I e smoke fog residue dust dew In heavy club use we recommend cleaning on a monthly basis Periodic cleaning will ensure longevity and crisp output 1 Use normal glas...

Page 6: ...n power and allow the unit ample time to cool before attempting to replace the lamp Lamp replacement has been made simple by incorporating the use of a removable front cover that is retained by thumb...

Page 7: ...th 10 dip switches dip switch 10 is reserved for special functions 2 Tempest 575H Warranty 1 YEAR LIMITED WARRANTY A American DJ hereby warrants to the original purchaser American DJ products to be fr...

Page 8: ...l Tempest 575H Voltage 120v 60Hz or 220v 50Hz Lamp ZB GLC Dimensions 27 5 x 27 5 x 9 5 Colors 6 Plus White Weight 44Lbs 22kgs Breaker 10A 120v 5A 220v Duty Cycle None DMX 1 Channel Sound Active Yes Wo...

Reviews: