background image

American DJ

®

  -  www.americandj.com  - Revo II™ Instruction Manual Page 6

American DJ

®

  -  www.americandj.com  - Revo II™ Instruction Manual Page 5

Power  Supply:

  Before  plugging  your  unit  in,  be  sure  the  source 

voltage in your area matches the required voltage for your American 
DJ

®

 Revo II.™ The American DJ

®

 Revo II

 is available in a 120v and 

220v  version.  Because  line  voltage  may  vary  from  venue  to  venue, 
you should be sure your unit voltage matches the wall outlet voltage 

before attempting to operate you fixture.  Also be sure to only use the 

included I.E.C. power cable supplied with the unit, this cable matches 
the voltage and current requirements of the unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 
communication  between  intelligent  fixtures  and  controllers. 

A  DMX 

controller sends DMX data instructions from the controller to the fix

-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX  Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of  different  manufactures  to  be  linked  together  and  operate  from  a 

single  controller,  as  long  as  all  fixtures  and  the  controller  are  DMX 

compliant.

  To  ensure  proper  DMX  data  transmission,  when  using 

several DMX fixtures try to use the shortest cable path possible. The 
order in which fixtures are connected in a DMX line does not influence 
the DMX addressing. For example; a fixture assigned a DMX address 
of 1 may be placed anywhere in a DMX line, at the beginning, at the 
end, or anywhere in the middle. Therefore, the first fixture controlled 
by the controller could be the last fixture in the chain. When a fixture 
is  assigned  a  DMX  address  of  1,  the  DMX  controller  knows  to  send 
DATA assigned to address 1 to that unit, no matter where it is located 
in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX 

and Master/Slave Operation): 

The Revo II™ can 

be controlled via DMX-512 protocol. The Revo II™ 

a four channel DMX unit. The DMX address is set 
electronically using the controls on the side panel of 
the unit. Your unit and your DMX controller require 
a standard 3-pin XLR connector for data input and 
data output (Figure 1). If you are making your own 
cables, be sure to use standard two conductor shielded cable (This 

 Revo II™   

                                                     Set Up

Figure 1

cable may be purchased at almost all professional sound and lighting 
stores). Your cables should be made with a male and female XLR con-
nector on either end of the cable. Also remember that DMX cable must 
be daisy chained and cannot be split.

 Revo II™   

 

 

                                 Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Summary of Contents for Revo II

Page 1: ...Slave configuration The Revo II comes with several built in programs When used as a stand alone unit or when used in multiples linked in a master slave configuration For best results use fog or specia...

Page 2: ...spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance Revo II Safety Precautions...

Page 3: ...address is set electronically using the controls on the side panel of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input and data output Figure 1 If you...

Page 4: ...d press ENTER 2 A number between 1 512 will be displayed and flashing Press the UP or DOWN buttons to find your desired address Press ENTER to set your desired DMX address SLND This will let you set u...

Page 5: ...er Slave mode You can daisy chain up to 16 units together to get a synchronized light show without the need of an external controller The units will react to sound chasing through the several built in...

Page 6: ...tor only The last unit in the chain will use the male XLR connector only For longer cable runs we suggest a terminator at the last fixture 2 On the Master unit find your desired show and set that show...

Page 7: ...warranty is void if the serial number has been altered or removed if the product is modified in any manner which American DJ Inc concludes after inspection affects the reliability of the product if th...

Page 8: ...s Colors RGB White Duty Cycle None DMX 4 Channels Sound Active Yes Working Position Any Safe Secure Position Warranty 3 Year 1095 days Voltage is preset at the factory and is not user selectable Pleas...

Reviews: