background image

ADJ Products, LLC  -  www.adj.com  - Pixel Pulse Bar Instruction Manual Page 5

ADJ Products, LLC  -  www.adj.com  - Pixel Pulse Bar Instruction Manual Page 6

P

ower Supply:

 The ADJ Pixel Pulse Bar contains a automatic voltage 

switch, which will auto sense the voltage when it is plugged into the 

power source. With this switch there is no need to worry about the cor-

rect power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 
DMX Linking: DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To ensure proper DMX data transmission, when using several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Pixel Pulse Bar can be controlled via DMX-512 protocol. The Pixel 

Pulse Bar has 3 DMX channel modes. The DMX address is set on the 

back panel of the Pixel Pulse Bar. Your unit and your DMX controller 

require a standard 3-pin XLR connector for data input and data output 

(Figure  1).  We  recommend  Accu-Cable  DMX 

cables. If you are making your own cables, be sure 

to use standard 110-120 Ohm shielded cable (This 

cable may be purchased at almost all pro lighting 

stores). Your cables should be made with a male 

and female XLR connector on either end of the 

cable. Also remember that DMX cable must be 

daisy chained and cannot be split.

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination. 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors. 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

  Pixel Pulse Bar                                                DMX Set Up

  Pixel Pulse Bar                                                DMX Set Up

Summary of Contents for Pixel Pulse Bar

Page 1: ...intelligent 5 zone color pixel wash The Pixel Pulse Bar has 3 operating modes sound active mode show mode or DMX controlled This fixture can be used as a stand alone unit or in a master slave con figu...

Page 2: ...bjects have fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate normally or exhibits a marked change in pe...

Page 3: ...at DMX cable must be daisy chained and cannot be split Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not con nec...

Page 4: ...his will let select your desired DMX channel mode 1 Press the either the MENU button until CHND is displayed press ENTER Either 1CH 4CH or 17CH will be displayed 2 Press the UP or DOWN buttons to find...

Page 5: ...the running mode the fixture will go into when the DMX signal is lost You can also set this as the operat ing mode you would like the unit to return to when power is Pixel Pulse Bar System Menu appli...

Page 6: ...ar has 3 DMX Modes a 1 Channel Mode 4 Channel Mode 17 Channel Mode See pages 14 16 for a detailed description of the DMX traits 2 To control your fixture in DMX mode follow the set up procedures on pa...

Page 7: ...ce press ENTER For more info see page 8 4 The slave units will now follow the Master unit Pixel Pulse Bar Master Slave Configuration Channel Value Function 1 SHOWS 0 7 BLACKOUT 8 37 SHOW 1 38 67 SHOW...

Page 8: ...8 GREEN 3 0 255 0 100 9 BLUE 3 0 255 0 100 10 RED 4 0 255 0 100 11 GREEN 4 0 255 0 100 12 BLUE 4 0 255 0 100 13 RED 5 0 255 0 100 14 GREEN 5 0 255 0 100 15 BLUE 5 0 255 0 100 16 MASTER DIMMER 0 255 0...

Page 9: ...nt prohibited by applicable law all implied warranties made by ADJ Products LLC in connection with this product including warranties of merchantability or fitness are limited in duration to the warran...

Page 10: ...the design of this unit and this manual are subject to change without any prior written notice Auto Sensing Voltage This fixture contains a automatic volt age switch which will auto sense the voltage...

Reviews: