background image

P

ower Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

Pearl LED Color™. The American DJ

®

 Pearl LED Color™ is available in 

a 120v and 220v version. Because line voltage may vary from venue to 

venue, you should be sure your unit voltages matches the wall outlet 

voltage before attempting to operate you fixture.  

DMX-512:

 

DMX is short for Digital Multiplex. This is a universal pro

-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav

-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter

-

minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller,  as  long  as  all  fixtures  and  the  controller  are  DMX  compli

-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The  Pearl  LED  Color™  can  be  controlled  via  DMX-512  protocol.  The 

Pearl LED Color™ is a two channel DMX unit. The DMX address is set 
on the bottom of the Pearl LED Color™. Your unit and your DMX con-
troller require a standard 3-pin XLR connector for 

data input and data output (Figure 1). If you are 

making your own cables, be sure to use standard 
two conductor shielded cable (This cable may be 
purchased  at  almost  all  pro  sound  and  lighting 
stores). Your cables should be made with a male 
and  female  XLR  connector  on  either  end  of  the 
cable.  Also  remember  that  DMX  cable  must  be 
daisy chained and can not be split.

©American DJ®  -  www.americandj.com  - Pearl LED Color™ User Manual Page 5

  Pearl LED Color™                                                    Set Up

©

American DJ Supply

®

  -  www.americandj.com  - Pearl LED Color™ User Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

 Pearl LED Color™  

 

 

                        Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con

-

nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 

may be implemented in a 3-pin XLR DMX line. When inserting stan-
dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be 
used, these adaptors are readily available at most electric stores. The 
chart below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Reviews: