background image

P

ower Supply:

 The American DJ

®

 Mega 24PRO contains a electronic 

ballast, which will auto sense the voltage when it is plugged into the 
power  source.  With  the  electronic  ballast  you  do  not  need  to  worry 
about wall voltage, this unit can be plugged in anywhere.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. A DMX controller sends DMX data instructions from 
the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 
controller,  as  long  as  all  fixtures  and  the  controller  are  DMX  compli-
ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 
DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Mega 24PRO can be a 3, 6, 7, 10, 12, or 16 channel DMX unit. The 
DMX address is set on the rear panel of the Mega 24PRO. Your unit and 
your DMX controller require a approved DMX-512 110 Ohm Data cable 
for data input and data output (Figure 1). We recommend Accu-Cable 
DMX cables. If you are making your own cables, be sure to use standard 
110-120 Ohm shielded cable (This cable may be 
purchased at almost all professional sound and 
lighting stores). Your cables should be made with 
a male and female XLR connector on either end 
of the cable. Also remember that DMX cable must 
be daisy chained and cannot be split.

©American DJ®  -  www.americandj.com  - Mega 24PRO Instruction Manual Page 5

  Mega 24PRO                                                             Set Up

©

American DJ®  -  www.americandj.com  - Mega 24PRO Instruction Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

 Mega 24PRO 

 

                                           Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 
may be implemented in a 3-pin XLR DMX line. When inserting stan-
dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be 
used, these adaptors are readily available at most electric stores. The 
chart below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Summary of Contents for Mega 24PRO

Page 1: ...olor wash This wash can be used in a stand alone mode or connected in a Master Slave configura tion The unit can also be controlled via DMX controller This unit has four operating modes Color mode Pro...

Page 2: ...ng amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled...

Page 3: ...can DJ www americandj com Mega 24PRO Instruction Manual Page 6 Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not...

Page 4: ...x fixtures 2 You will also have to link the power cords to each other as you did with the XLR cables 3 Using the Master unit choose your desired mode or program and connect the Slave unit or units The...

Page 5: ...GREEN 1 255 0 100 3 BLUE 1 255 0 100 Mega 24PRO DMX Values Functions 7 Channel Mode Channel Value Function 1 RED 1 255 0 100 2 GREEN 1 255 0 100 3 BLUE 1 255 0 100 4 COLOR MACROS 0 OFF 1 7 BASTARD AM...

Page 6: ...LUE 192 199 PALE YELLOW GREEN 200 207 MOSS GREEN 208 215 PRIMARY GREEN 216 223 DOUBLE CTB 224 231 FULL CTB 232 239 HALF CTB 240 247 DARK BLUE 248 255 WHITE 5 STROBING PROGRAM SPEED STROBING 0 15 OFF 1...

Page 7: ...100 5 GREEN 2 1 255 0 100 6 BLUE 2 1 255 0 100 7 1 255 COLOR MACROS PLEASE SEE CH 4 IN 7 CH MODE 8 STROBING PROGRAM SPEED STROBING 0 15 OFF 16 255 SLOW FAST PROGRAM SPEED 0 239 SLOW FAST 240 255 SOUND...

Page 8: ...R DIMMER 0 10 Mega 24PRO DMX Values Functions 16 Channel Mode Mega 24PRO RGB Macro Chart BASTARD AMBER MEDIUM AMBER PALE AMBER GOLD GALLO GOLD GOLDEN AMBER LIGHT RED MEDIUM RED MEDIUM PINK BROADWAY PI...

Page 9: ...r improvements upon its products without any obligation to include these changes in any products theretofore man ufactured No warranty whether expressed or implied is given or made with respect to any...

Page 10: ...ase Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Auto Sensing Voltage This fixture contains a electronic bal l...

Reviews: