background image

©

American DJ

®

  -  www.americandj.com - Galaxian Move™ Instruction Manual Page 9

©

American DJ

®

  -  www.americandj.com - Galaxian Move™ Instruction Manual Page 10

  Galaxian Move™   

 

 

                       Set Up

  Galaxian Move™   

 

 

                       Set Up

ommend Accu-Cable DMX cables. If you are making your own cables, 
be sure to use standard 110-120 Ohm shielded cable (This cable may 
be  purchased  at  almost  all  professional  sound  and  lighting  stores). 
Your cables should be made with a male and female XLR connector on 
either end of the cable. Also remember that DMX cable must be daisy 
chained and cannot be split.

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan

-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 
these adaptors are readily available at most electric stores. The chart 
below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Pin 5 - Do Not Use

Pin 4 - Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Summary of Contents for Galaxian Move

Page 1: ...re programmed show or controlled via DMX For best results use fog or special effects smoke to enhance the beams projections Customer Support American DJ provides a toll free customer sup port line to...

Page 2: ...is unit is intended for indoor use only use of this product out doors voids all warranties During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable mat...

Page 3: ...e exposure In the laser safety regulation it is not legal to aim Class 3R lasers in areas which people can get exposed This is true even if it is aimed below people s faces such as on a dance floor Do...

Page 4: ...tures to be linked together and operate from a sin gle controller as long as all fixtures and the controller are DMX com pliant To ensure proper DMX data transmission when using several DMX fixtures t...

Page 5: ...e Socket XLR Pin Configuration 3 Hot 2 Cold 2 Cold 3 Hot XLR Female Socket Pin 3 Data True positive Pin 2 Data Compliment negative Pin 1 Ground Special Note Line Termination When longer runs of cable...

Page 6: ...will now be displayed and flashing Press the UP or DOWN buttons to find your desired address Press ENTER to set your desired DMX address SHND This will let you choose one of the four prepro grammed s...

Page 7: ...r DOWN buttons until Yes is displayed press ENTER to confim The fixture will now be in Blackout mode To deactivate Blackout mode select No and press Enter I PAN Pan Inversion 1 Tap the MENU button unt...

Page 8: ...ou choose DMX control mode This function will allow you to control each individual fixtures traits with a standard DMX 512 controller such as the Elation Show Designer Master Slave Operation This func...

Page 9: ...NTER 3 The optional UC3 Controller not included may be used to con trol different functions including blackout Show Mode This mode allows either a single unit or several units linked together to run o...

Page 10: ...solutions No light output from the unit 1 Be sure you have connected your unit into a standard 120v wall outlet 2 Be sure the external fuse has not blown The fuse is located on the rear panel of the u...

Page 11: ...ole responsibility of American DJ Inc under this warranty shall be limited to the repair of the product or replace ment thereof including parts at the sole discretion of American DJ All products cover...

Page 12: ...und Active Yes Working Position Any Safe Secure Position Warranty 90 Days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior...

Reviews: