background image

 Fusion Scan 250 EX™   

 

                 DMX Traits

  

Channel 

    Value 

 

          Function

         

6

             

                 

       

                        LASER

                            0 - 7                                 LASER OFF   
                            8 - 15                               LASER ON
                          16 - 131          LASER INTENSITY (VERY SUBTLE)
                        132 - 247                          SOUND ACTIVE
                        248 - 255                              LASER ON       

 Fusion Scan 250 EX™   

 

   Lamp Replacement

Caution:

 

Always  replace  with  the  exact  same  type  lamp  and  fuse, 

unless  otherwise  specified  by  an  authorized  American  DJ

®

  service 

technician. Replacing with anything other than the specified part can 
damage your unit and will void your manufactures warranty.

Warning: 

If  you  continue  to  blow  lamps  or  fuses,  STOP  using  the 

unit. Contact customer support for further instructions, you may have 
to return the unit for servicing. Continuing to use the unit may cause 
serious damage.

Caution!  Never  open  the  unit  when  in  use.  Always  disconnect  the 
main power before attempting to replace the lamp. 
1.  Be sure to follow the proper procedures when handling halogen      
     bulbs.
2.  Lamp replacement has been made simple by incorporating the  
     use of two phillips screws.
3.  Loosen and remove the phillips screws on the front bottom cover.
4.  Remove the lamp cover and replace the bulb.
5.  Reassemble.

Remember to always replace with the exact same type lamp and 
fuse,  unless  otherwise  specified  by  an  authorized  American  DJ 
service technician. 

This fixture is fitted with a halogen lamp which is 

highly  susceptible  to  damage  if  improperly  han-
dled. Never touch the lamp with your bare fingers 
as the oil from your hands will shorten lamp life. 

Also, never move the fixture until the lamps have 

had  ample  time  to  cool.  Remember,  lamps  are 
not covered under warranty conditions.

American DJ

®

  -  www.americandj.com  - Fusion Scan 250 EX™ Instruction Manual Page 18

American DJ

®

  -  www.americandj.com  - Fusion Scan 250 EX™ Instruction Manual Page 17

  Fusion Scan 250 EX™ 

                                Fuse Replacement

Locate  and  remove  the  unit’s  power  cord.  Once  the  cord  has  been 
removed  located  the  fuse  holder  located  inside  the  power  socket. 
Insert a flat-head screw driver into the power socket and gently pry 
out the fuse holder. Remove the bad fuse and replace with a new one. 
The fuse holder has a built-in socket for a spare fuse be sure not to 
confuse the spare fuse with active fuse.

 Fusion Scan 250 EX™    

       Protective Mirror Cover

A metal cover is provided to protect the scanner mirror during 
transportation and storage. The protective cover is held in place 
by two thumb screws.

Thumb Screws

Summary of Contents for Fusion Scan 250 EX

Page 1: ...s a six channel DMX intel ligent fixture The fixture can used in two different operating modes Sound Active or DMX controlled The Fusion Scan 250 EX can be used as a stand alone fixture or used in mul...

Page 2: ...PORTANT When installing this projector make sure that it is mounted in a manner that prevents the audience from looking directly into the beam and the beam from striking the audience Fusion Scan 250 E...

Page 3: ...ion it is not legal to aim Class 3R lasers in areas which people can get exposed This is true even if it is aimed below people s faces such as on a dance floor Do not operate the laser without first r...

Page 4: ...s most controllers only have a DATA OUT terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as lon...

Page 5: ...Grounding the shield could cause a short circuit and erratic behavior DMX512 IN 3 PIN XLR SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTR...

Page 6: ...he MENU button until TEST is displayed press ENTER 2 The fixture will now run a self test FHRS With this function you can display the running time Fusion Scan 250 EX System Menu Fusion Scan 250 EX Sys...

Page 7: ...Operation Sound Active Mode This mode allows a single unit or several units linked together to run to the beat of the music 1 Once you plug the fixture in Sound Active mode is activated auto matically...

Page 8: ...fixtures 1 and 3 set the fixture 1 to MAST and set fixture 3 to SL 1 and set fixtures 2 4 to SL 2 Fixtures 1 2 will run the same and fixtures 2 4 will run opposite This makes a great light show 5 The...

Page 9: ...Reassemble Remember to always replace with the exact same type lamp and fuse unless otherwise specified by an authorized American DJ service technician This fixture is fitted with a halogen lamp whic...

Page 10: ...pplicable law all implied warranties made by American DJ Inc in connection with this product including warranties of merchantability or fitness are limited in duration to the warranty period set forth...

Page 11: ...sion Scan 250 EX Notes American DJ www americandj com Fusion Scan 250 EX Instruction Manual Page 22 American DJ www americandj com Fusion Scan 250 EX Instruction Manual Page 21 Fusion Scan 250 EX Note...

Page 12: ...Warranty 1 Year 365 days Voltage is preset at the factory and is not user selectable Please Note Specifications and improvements in the design of this unit and this manual are subject to change withou...

Reviews: