Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

Fusion  Scan  250  EX.™  The  American  DJ

®

  Fusion  Scan  250  EX

  is 

available in a 120v and 220v version. Because line voltage may vary 
from venue to venue, you should be sure your unit voltage matches the 

wall outlet voltage before attempting to operate you fixture.  Also be 

sure to only use the included I.E.C. power cable supplied with the unit, 

this cable matches the voltage and current requirements of the unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 
communication  between  intelligent  fixtures  and  controllers. 

A  DMX 

controller sends DMX data instructions from the controller to the fix

-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX  Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of  different  manufactures  to  be  linked  together  and  operate  from  a 

single  controller,  as  long  as  all  fixtures  and  the  controller  are  DMX 

compliant.

  To  ensure  proper  DMX  data  transmission,  when  using 

several DMX fixtures try to use the shortest cable path possible. The 
order in which fixtures are connected in a DMX line does not influence 
the DMX addressing. For example; a fixture assigned a DMX address 
of 1 may be placed anywhere in a DMX line, at the beginning, at the 
end, or anywhere in the middle. Therefore, the first fixture controlled 
by the controller could be the last fixture in the chain. When a fixture 
is  assigned  a  DMX  address  of  1,  the  DMX  controller  knows  to  send 
DATA assigned to address 1 to that unit, no matter where it is located 
in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX 

and  Master/Slave  Operation): 

The  Fusion  Scan 

250 EX™ can be controlled via DMX-512 protocol. 

The Fusion Scan 250 EX™ a six channel DMX unit. 

The  DMX  address  is  set  electronically  using  the 
controls on the side panel of the unit. Your unit and 

your DMX controller require a standard 3-pin XLR 

connector  for  data  input  and  data  output  (Figure 
1). If you are making your own cables, be sure to use standard two 

 Fusion Scan 250 EX™   

                                 Set Up

Figure 1

Summary of Contents for Fusion Scan 250 EX

Page 1: ...s a six channel DMX intel ligent fixture The fixture can used in two different operating modes Sound Active or DMX controlled The Fusion Scan 250 EX can be used as a stand alone fixture or used in mul...

Page 2: ...PORTANT When installing this projector make sure that it is mounted in a manner that prevents the audience from looking directly into the beam and the beam from striking the audience Fusion Scan 250 E...

Page 3: ...ion it is not legal to aim Class 3R lasers in areas which people can get exposed This is true even if it is aimed below people s faces such as on a dance floor Do not operate the laser without first r...

Page 4: ...s most controllers only have a DATA OUT terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as lon...

Page 5: ...Grounding the shield could cause a short circuit and erratic behavior DMX512 IN 3 PIN XLR SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTR...

Page 6: ...he MENU button until TEST is displayed press ENTER 2 The fixture will now run a self test FHRS With this function you can display the running time Fusion Scan 250 EX System Menu Fusion Scan 250 EX Sys...

Page 7: ...Operation Sound Active Mode This mode allows a single unit or several units linked together to run to the beat of the music 1 Once you plug the fixture in Sound Active mode is activated auto matically...

Page 8: ...fixtures 1 and 3 set the fixture 1 to MAST and set fixture 3 to SL 1 and set fixtures 2 4 to SL 2 Fixtures 1 2 will run the same and fixtures 2 4 will run opposite This makes a great light show 5 The...

Page 9: ...Reassemble Remember to always replace with the exact same type lamp and fuse unless otherwise specified by an authorized American DJ service technician This fixture is fitted with a halogen lamp whic...

Page 10: ...pplicable law all implied warranties made by American DJ Inc in connection with this product including warranties of merchantability or fitness are limited in duration to the warranty period set forth...

Page 11: ...sion Scan 250 EX Notes American DJ www americandj com Fusion Scan 250 EX Instruction Manual Page 22 American DJ www americandj com Fusion Scan 250 EX Instruction Manual Page 21 Fusion Scan 250 EX Note...

Page 12: ...Warranty 1 Year 365 days Voltage is preset at the factory and is not user selectable Please Note Specifications and improvements in the design of this unit and this manual are subject to change withou...

Reviews: