background image

LUBRICATION

an  automatic  lubricator  can  be  installed  in  the  air  line  just  ahead  of  the  motor.  the  lubricator  should  be
adjusted  to  feed  one  drop  of  oil  per  minute.  lubrication  is  necessary  for  all  internal  moving  parts  and  rust
prevention. excessive moisture in the air line can cause rust formation in the motor and might also cause ice
to form in the muffler due to the expansion of air through the motor. the moisture problem can be corrected
by installing a moisture separator in the line and also be installing an aftercoolor between the compressor and
air receiver.

uSe a DeterGeNt Sae #10 autoMotiVe eNGiNe oil.

SERVICING AIR MOTOR

if the motor is sluggish or inefficient, try flushing with recommended solvent. the recommended solvent for
air motors and  lubricated pumps is Gast flushing Solvent, Part # ah255 or ah255a, Demkote 2x726 safety
solvent, inhibisol Safety Solvent or Dow chemical chlorothane.

to flush the unit, disconnect air line from the coupler plate and remove the felt inside the muffler assembly.
add  several  teaspoons  of  solvent  directly  into  the  air  motor  fitting.  rotate  the  fan  shaft  by  hand  in  both
directions for a few minutes. connect motor to an adjustable air supply. Slowly apply pressure until there is
no trace of solvent in exhausted air system. reinstall the felt insert and secure the muffler cap.

CAUTION:

foreign material exiting the air motor can be hazardous. Solid or liquid material exiting the
unit  can  cause  eye  or  skin  damage.  Keep  away  from  air  stream.  Keep  face  away  from
exhaust port. eye protection is required.

CAUTION:

flush unit only in a well-ventilated area.

relubricate the motor by squirting a drop of oil in the chamber. if the vanes need replacing or foreign materials
are present in motor chamber, an experienced mechanic may remove the end plate opposite the drive shaft end.
Do Not Pry With a ScreWDriVer.
it will dent the surface of the plate and body causing leaks. a puller tool should be used which will remove the
end plate while maintaining the position of the shaft. New vanes should have the edge with the corners cut on
angle or the notched edge towards the bottom of the vane slot.

If motor requires service, it is highly recommended that the user remove the motor from the housing as
per the instructions provided in this manual and return it to the factory for repair.

A  service  kit  is  available;  however  it  should  only  be  installed  by  a  qualified  mechanic.  The  tolerances
inside the air motor must be maintained to insure top operating performance.

SHUTDOWN AND STORAGE PROCEDURE

1) turn off air intake supply and remove plumbing.

2) remove air motor from the connecting machinery.

3) use clean, dry air at low pressure to “flush out” condensates, such as water.

4) re-lubricate the air motor with a squirt of oil in the chamber. rotate the shaft by hand several times.

5) Plug or cap each port. the unit is now ready for storage. 

8

Summary of Contents for VAF-3000P

Page 1: ... in Class I Groups A B C and D Class II Groups E F and G and Class III Purchase Date_______________________ Serial No _______________________ Dealer_____________________________________________________________ Americ Corporation 785 Bonnie Lane Elk Grove Village IL 60007 USA Phone 847 364 4646 Fax 847 364 4695 ...

Page 2: ...rms and obligations 1 introduction 2 General Safety information and operation 3 exploded View of the Vaf 3000P 4 Parts list 5 air Motor Precautions and operating Specs 6 trouble Shooting 7 lubrication and Servicing the air Motor 8 ...

Page 3: ... beyond americ s control this limited warranty does not apply if the serial number has been removed obliterated or defaced americ corporation reserves the right to make changes to the Vane axial fan in design materials or specifications as necessary and without prior notice americ shall not be obliged to make alterations or modifications to existing products previously manufactured to obtain repla...

Page 4: ...y does exist however that the Vane axial fan can be subjected to applications not intended by americ Misuse and or misapplication of the Vane Axial Fan can lead to the possibility of serious damage injury or even death anyone operating the Vane axial fan should refer to current oSha job safety and health rules and regulations pertaining to the construction industry with a particular emphasis on 29...

Page 5: ...zarDouS locatioNS 1 CAUTION Ground unit at lug on coupler plate 2 Air supply lines shall be made of electrically conductive material in accordance with the recommended practice on static electricity NFPA 77 and or any other applicable local code INSTRUCTIONS FOR OPERATION AND CARE oPeratioN StaNDarDS your new Vaf 3000P comes to you completely assembled and ready to operate carefully inspect unit f...

Page 6: ...VAF 3000P PICTORIAL BREAKDOWN 4 ...

Page 7: ...6 17 00852a fan blade 17 104 50028 1 2 oD tube 18 104 50032 Muffler 19 Motor assembly 104 50014 Motor 104 50015 Motor Mount 104 50016 Motor endplate 104 50017 Motor bolt 104 50018 lock Washer 09 00889a Vane 104 50020 Vane to Motor bolts 104 50021 Star Washer 104 50022 lock Washer 104 50023 Nut 20 Motor connection 104 50025 Pipe Nipple 104 50026 hex bushing 104 50027 90 Swivel Slip on 21 03 00983a ...

Page 8: ...in excess of the recommended operating maximums below ambient temperature should not exceed 121 c 250 f SAFETY SYMBOL When you see this symbol CAUTION be aware that personal injury or property damage is possible the hazard is explained in the text following the symbol CAUTION Severe personal injury or death coulD occur if hazard is ignored iNterNal oPeratiNG MaxiMuMS Motor Maximum Maximum Maximum ...

Page 9: ...uct length 4 Worn motor vanes 1 remove motor and replace damaged motor mounts 2 Perform maintenance and check line to air supply 1 remove and replace motor replace fan blade as necessary 2 replace fan blade 3 clean fan blade 1 remove motor and replace damaged motor mounts 2 replace fan blade if necessary 3 replace housing unit as necessary 1 Supply 100 psi air 2 increase size of compressor and or ...

Page 10: ...foreign material exiting the air motor can be hazardous Solid or liquid material exiting the unit can cause eye or skin damage Keep away from air stream Keep face away from exhaust port eye protection is required CAUTION flush unit only in a well ventilated area relubricate the motor by squirting a drop of oil in the chamber if the vanes need replacing or foreign materials are present in motor cha...

Page 11: ...cing you Disconnect air hoses from the motor by pushing in on the ferrule lock ring while pulling on hoses Step three use a 13 16 open end wrench to spin off brass hex fittings from the air motor Note a 3 4 open end wrench may also be needed to spin off air connection ferrules of the 90º elbow because of limited space Step four lay unit down with the fan blade facing up remove the nylon nut that h...

Page 12: ...al assistance REINSTALLING THE AIR MOTOR INTO THE VAF 3000P HOUSING Step one Prepare motor for installation by removing the shipping plugs from the air motor ports lay the Vaf 3000P face down on a firm work surface Step two carefully position air motor into the housing assembly with the motor shaft through the front mounting plate be sure to align the air fitting holes of the motor and housing so ...

Page 13: ...t ring and grounding stud ring to the front of the unit s housing assemble bolt with flat washer first then the ground stud ring and finally the star washer this bolt assembly is then threaded through the grill and duct ring into unit s housing repeat steps to install grill duct ring and grounding stud ring to the rear of unit s housing you should use a 1 4 ratchet and a 7 32 socket for this proce...

Page 14: ...785 Bonnie Lane Elk Grove Village IL 60007 Tel 847 364 4646 800 364 4642 Fax 847 364 4695 Email sales americ com www americ com ...