It is importantthat you readthese instructions before using your new purchaseand we strongly recommend thatyou keep them ina safe place forfuture reference.
Mini Portable Air Conditioner
Model APC2000E
Owner’s
Manual
Page 1: ...tant that you read these instructions before using your new purchase and we strongly recommend that you keep them in a safe place for future reference Mini Portable Air Conditioner Model APC2000E Owne...
Page 2: ...Don t forget to register your Amcor purchase online and view our broad selection of innovative products www amcorgroupusa com...
Page 3: ...Table of Contents 1 ThankYou 2 Parts 3 Safety 4 Positioning 5 Operation 6 7 Emptying the WaterTank 8 Cleaning 9 Storage 10 Troubleshooting 10 Specifications 11 Limited Warranty 12...
Page 4: ...l on the unit The mini air conditioner is intended exclusively for the use for which it was created Amcor is not responsible for any damage caused by improper use IMPORTANT The unit is designed for in...
Page 5: ...Castors 10 Power cord 5 8 7 9 6 4 1 2 3 10 Parts 3 TEST RESET Reset Button Green Light Test Button OPTIONAL Carbon Filter If Unit Is Not Operating 1 If unit doesn t turn on press top reset button on p...
Page 6: ...bjects This products is not made for DIY repair If there is a risk of liquid falling on the unit Do not use your air conditioner IMPORTANT The first time that you use the unit please ensure that it ha...
Page 7: ...dehumidi fier If possible leave interior doors ajar to allow air circulation Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier there and later movin...
Page 8: ...ehumidify the corresponding LED will lit LO green for mild dehumidification or HI orange for strong dehumidification When the relative humidity in the room is high and you want to dry the room quickly...
Page 9: ...ly stops the WATER TANK FULL LED will turn red to signal that the tank must be emptied Important The compressor will start approximately 3 minutes after the unit is turned on this will help prolong th...
Page 10: ...the water tank The water full sensor will no longer be able to detect the water level correctly without the float and water may leak from the water tank 2 If the water tank is dirty wash it with cold...
Page 11: ...der mold spores and pollen It is advisable to check the filter on a regular basis at least monthly and after storage and clean as necessary Extract the filter holder Use a vacuum cleaner or tap the fi...
Page 12: ...ork The filter is dirty Clean or replace the filter Air inlet or air outlet blocked Remove the blockage No air is discharged The filter is dirty Clean or replace the filter Operation is noisy The unit...
Page 13: ...apacity 1 000 BTUs Dehumidification 25 pints 24h Water tank capacity 13 pints Operating temperature 41 95 F Dimensions 14 W x 23 H x 9 D Net weight 26 5 lbs Reminder Waste electrical products must not...
Page 14: ...i ability To obtain warranty service the defective product or part must be shipped or delivered to Amcor s authorized service center All postage insurance and shipping charges are the responsibility o...
Page 15: ...ual no fue dise ado o 4 reparado o alterado de alguna manera que haya afectado adversamente su desempe o o fi abilidad Para obtener el servicio de garant a el producto o parte defectuosa debe ser envi...
Page 16: ...eguro especifi caciones Modelo APC 2000E Alimentaci n 115V 60 Hz 1Ph Consumo de energ a deshumidificaci n 250 watts Consumo de energ a refrigeraci n 240 watts Capacidad de refrigeraci n 1 000 BTUs Des...
Page 17: ...funcionar La funci n de deshumidificaci n no funciona El filtro est sucio Limpie o cambie el filtro Entrada o salida de aire bloqueada Retire el obst culo No sale aire El filtro est sucio Limpie o cam...
Page 18: ...o humo part culas de animales esporas mohosas y polen Se aconseja revisar el fi ltro regularmente como m nimo una vez al mes y despu s de guardado y limpiarlo en caso necesario Extraiga el soporte del...
Page 19: ...O quite el fl otador del dep sito de agua El sensor de dep sito lleno no podr detectar correctamente el nivel del agua sin el fl otador y el agua podr a derramarse 2 Si el dep sito est sucio puede lav...
Page 20: ...indicando que debe vaciar el dep sito Rejilla cerrada modo deshumidificaci n Rejilla abierta modo refrigeraci n Importante El compresor arrancar aproximadamente a los 3 minutos de encender el aparato...
Page 21: ...parato empezar a deshumidifi car y se encender el indicador correspondiente lo verde para refrigeraci n m nima o hi naranja para m xima Cuando la humedad relativa de la sala es alta y desee deshumidif...
Page 22: ...d de la casa hacia l Un pasillo c lido o un rellano son una excelente posici n para el deshumidifi cador Si es posible deje las puertas interiores entreabiertas para que circule el aire O bien si en u...
Page 23: ...ra exterior Ubicaci n muy h mida permanente Si los cables de energ a est n deshilachados o cortados En presencia de ni os sin un adulto que los cuide Si el cable de extensi n puede estar sobrecargado...
Page 24: ...a 9 Ruedas 10 Cable de red 5 8 7 9 6 4 1 2 3 10 3 OPCIONAL Filtro de carbono TEST RESET Bot n Reset de reposici n Luz Verde Pruebe el Bot n Si la unidad no opera 1 Si la unidad no prende Oprima e repo...
Page 25: ...aparato Este aparato se ha fabricado exclusivamente para el uso indicado Amcor no se hace responsable de da os causado por un uso incorrecto El aparato es seguro sin embargo al igual que con todos los...
Page 26: ...ndice 1 gracias 2 componentes 3 seguridad 4 colocaci n 5 funcionamiento 6 vaciado del dep sito de agua 7 limpieza 8 conservaci n 9 fallos 9 especifi caciones 10 garant a limitada por un a o 11...
Page 27: ...No se olv de registrar su producto en l nea y ver nuestra selecci n ancha de productos innovadores www amcorgroupusa com...
Page 28: ...a estas instrucciones antes de utilizar su nuevo producto y recomendamos encarecidamente que las conserve en un lugar seguro para referencia futura Mini aire acondicionado port til Modelo APC2000E Man...