USER
MANUAL
914NG
T
ECHNICAL
S
HEET
D.40
7845285-06 03/20
subject to change without notice
D.17
ADDITIONAL STABILIZERS
Additional stabilizers must be chosen so that:
- the installation is stable (see Installer Manual)
- the max. force acting on the additional stabilizers, F
s
, is lower than the max. load allowed by the
stabilizers itself, R
max
.
F
s
= M
dyn
/ X
s
F
s
≥ 0.6 F
sg
where:
M
dyn
: max. dynamic moment of the crane
X
s
: distance between column axis - stab. cylinder
F
sg
: max force on stabilizer leg
Check that: F
s
≤
R
max
R
max
is given in the technical specifications of the
additional stabilizers.
X
s
- In addition, CE additional stabilizer must be equipped with safety devices integrated with the
crane's stability control system. Therefore we recommend to install the following models designed
by the crane's manufacturer:
Code
Spread
(m)
Weight
(kg)
R
max
(kg)
Overall dimensions
BxHxS
(mm)
7850088
2.00
155
6250
2160x770x190
7850086
3.32
220
6250
2285x780x240
7850087
3.32
235
6250
2285x780x240
For further information see the User Manual for outriggers.