TASK 1
I
NSTALLING
THE
SMD17K
1.1 Location
1.1.1 IP50 Rated Units (SMD17K-M12)
SMD17K units that are IP50 rated are suitable for use in an industrial environment that meet the following
criteria:
Only non-conductive pollutants normally exist in the environment, but an occasional temporary con-
ductivity caused by condensation is expected.
Transient voltages are controlled and do not exceed the impulse voltage capability of the product’s insu-
lation.
These criteria are equivalent to the
Pollution Degree 2
and
Over Voltage Category II
designations of the Inter-
national Electrotechnical Commission (IEC).
1.1.2 IP64 Rated Units (SMD17K-M12S)
SMD17K units that are IP64 rated are suitable for use in an industrial environment that meet the following
criteria:
Conductive pollution occurs, or dry, non-conductive pollution occurs which becomes conductive due to
condensation is to be expected.
Transient voltages are controlled and do not exceed the impulse voltage capability of the product’s insu-
lation.
These criteria are equivalent to the
Pollution Degree 3
and
Over Voltage Category II
designations of the Inter-
national Electrotechnical Commission (IEC).
1.1.3 IP65/7 Rated Units (SMD17K-M12P)
SMD17K units that are IP65/7 rated are suitable for use in an industrial environment that meet the following
criteria:
Continuous conductivity occurs due to conductive dust, rain, or other wet conditions.
Transient voltages are controlled and do not exceed the impulse voltage capability of the product’s insu-
lation.
These criteria are equivalent to the
Pollution Degree 4
and
Over Voltage Category II
designations of the Inter-
national Electrotechnical Commission (IEC).
1.2 Safe Handling Guidelines
1.2.1 Prevent Electrostatic Damage
Electrostatic discharge can damage the SMD17K units. Follow these guidelines when
handling the unit.
1) Touch a grounded object to discharge static potential before handling the unit.
2) Work in a static-safe environment whenever possible.
3) Wear an approved wrist-strap grounding device.
4) Do not touch the pins of the network connectors or I/O connector.
5) Do not disassemble the unit
6) Store the unit in its shipping box when it is not in use.
Summary of Contents for SMD17K
Page 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S292...
Page 6: ...TABLE OF CONTENTS SMD17K User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Page 48: ...CALCULATING MOVE PROFILES SMD17K User Manual ADVANCED MICRO CONTROLS INC 48 Notes...
Page 76: ...COMMAND DATA FORMAT SMD17K User Manual ADVANCED MICRO CONTROLS INC 76 Notes...
Page 94: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...
Page 96: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 96...
Page 98: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 98...