PROFINET A
CYCLIC
D
ATA
F
ORMATS
PROFINET Protocol
ADVANCED MICRO CONTROLS INC.
80
P980 - Number List of Defined Parameters
This parameter is an array of values that lists the parameter numbers of parameters available on the NR60E2.
Array [0..9] of Unsigned16 Integer
Table R6.7 P980 - Number of Defined Parameters
P65000 - Preset Value
This read / write parameter sets the preset/offset value associated with the NR60E2. A handshake protocol in
the cyclic data controls when this parameter is applied to the position value reported by the NR60E2.
Read/Write
Unsigned32 Integer
Range: 0 to {Total Measurement Range (TMR) - 1}.
Index
Sub
Meaning
Value
Access
980
0
P922 - Telegram Selection
922
RO
980
1
P925 - Maximum life sign failures
that may be tolerated
925
RO
980
2
P964 - Device Identification
964
RO
980
3
P965 - Profile Identification
965
RO
980
4
P971 - Store local parameters to
non-volatile memory
971
RO
980
5
P974 - Base Mode Parameter
Access Service Identification
974
RO
980
6
P975 - DO Identification
975
RO
980
7
P979 - Sensor Format
979
RO
980
8
P65000 - Preset Value
65000
RO
980
9
P65001 - Operating Status
65001
RO
Summary of Contents for NR60E2
Page 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual E2 Technology E2 Technology Manual 940 0D161...
Page 6: ...TABLE OF CONTENTS NR60E2 User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Page 20: ...NR60 SPECIFICATIONS NR60E2 User Manual ADVANCED MICRO CONTROLS INC 20 Notes...
Page 44: ...PROTOCOL SPECIFIC INFORMATION NR60E2 User Manual ADVANCED MICRO CONTROLS INC 44 Notes...
Page 52: ...IMPLICIT COMMUNICATIONS WITH AN EDS EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 52 Notes...
Page 58: ...IMPLICIT COMMUNICATIONS WITHOUT EDS EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 58 Notes...
Page 70: ...CIP POSITION SENSOR OBJECT EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 70 Notes...
Page 90: ...PROFINET CYCLIC DATA FORMATS PROFINET Protocol ADVANCED MICRO CONTROLS INC 90 Notes...
Page 98: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...