Input Data Format
ADVANCED MICRO CONTROLS INC.
6
76
Data Attribute 1: LS Setpoint Programming Data
Figure 6.3 LS Setpoint Data Format (Data Attribute 1)
EtherNet/IP
Address
Modbus
Address
Bit Number
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
Ackno
wled
ge
Heartbeat
Ha
rd
wa
re
Fa
ult
Resolver Fault
Program Fault
Bits
RPM Clamped
Output Forced
0
0
0
0
0
1
1
1
Selected Output Point Number
(See Word 2, Command Block 1, page 54)
2
2
Programmed FROM Setpoint 1
3
3
Programmed TO Setpoint 1
4
4
ON Stitch Distance 1
5
5
OFF Stitch Distance 1
6
6
Programmed FROM Setpoint 2
7
7
Programmed TO Setpoint 2
8
8
ON Stitch Distance 2
9
9
OFF Stitch Distance 2
10
10
Programmed FROM Setpoint 3
11
11
Programmed TO Setpoint 3
12
12
ON Stitch Distance 3
13
13
OFF Stitch Distance 3
14
14
Programmed FROM Setpoint 4
15
15
Programmed TO Setpoint 4
16
16
ON Stitch Distance 4
17
17
OFF Stitch Distance 4
18-19
18-19
Not Used