y
y
x
25
o
Minimum Usage 18mm
Minimum Usage 18mm
C 5/ C 30/ C 60 volume controls
INSTALLATION MANUAL
C 5/ C 30/ C 60
Volume controls
1
Connect volume controllers according wiring diagrams below. Select requested mode: passive or active .
C 5 volume control for 100 V audio lines
C 30/ C 60 volume control for 100 V audio lines
WIRING DIAGRAM
K1
SW-1*1 1WAY
104
CL1
SRS-24VDC-SH
2
1
5
6
4
3 OUT
RS1
IN
N1
IN
GND
GND
OUT
G
+24V
DG127-6
6
5
4
3
2
1
100V
+
+
_
_
Amp.
Speaker
24
V
15k
22k
47k
100k
5.6k
5.6k
5.6k
5.6k
5.6k
5.6k
5.6k
5.6k
5.6k
7.5k
7.5k
5.6k
10k
A
P
Switch for active or passive mode selection.
K1
SW-1*11WAY
104
CL1
SRS-24VDC-SH
2
1
5
6
4
3 OUT
RS1
235BYQ
IN
N1
IN
GND
GND
OUT
G
+24V
DG127-6
6
5
4
3
2
1
100V
+
+
_
_
Amp.
Speaker
24
V
A
P
Switch for active or passive mode selection.
Passive mode: C X attenuates the volume if 24 V is not connected to 24 V terminal.
After the voltage supplying, C X sets the maximum volume level.
P
Active mode: C X set the maximum volume level if 24 V is not connected to 24 V terminal.
After the voltage supplying, C X starts attenuate volume.
A