1022 D 

 

Standard Monitor 

 
 
 
 

INSTRUCTIONS 

AMC-1022 D WITH STANDARD SENSOR 

 
 

INSTALLATION AND OPERATING INSTRUCTIONS 

FOR THE AMC-1022 D SENSOR UNIT 

 
 
 
 
 
 
 
 
 
 
 

IMPORTANT: 

Please read these installation and operating instructions completely 
and carefully before starting. 

 
 
 
 
 

filename: Manual_amc1022D.doc 

Revised, 5/21/2002 

Copyright ©, May 2001, AMC 

 

The Armstrong Monitoring Corporation 

215 Colonnade Road South, Nepean, Ontario, Canada  K2E 7K3 

Tel: (613) 225-9531  •  Fax: (613) 225-6965  •  U.S. & Can. Toll Free: (800) 465-5777 

E-mail: [email protected]  •  Internet: www.armstrongmonitoring.com/gas/ 

Summary of Contents for 1022 D

Page 1: ...tion and operating instructions completely and carefully before starting filename Manual_amc1022D doc Revised 5 21 2002 Copyright May 2001 AMC The Armstrong Monitoring Corporation 215 Colonnade Road S...

Page 2: ......

Page 3: ...UCT RETURN iii 2 PRODUCT INFORMATION iv 3 PRODUCT DESCRIPTION 1 4 INSTALLATION 6 4 1 LOCATION AND MOUNTING 6 4 2 WIRING OF THE MONITOR SENSOR MODULE S 6 4 3 CABLE SELECTION 6 5 OPERATION AND CALIBRATI...

Page 4: ...AMC 1022D Monitor ii NOTE This page intentionally left blank...

Page 5: ...operation of this equipment AMC shall have no liability for labour or freight costs or any other costs or charges in excess of the amount of the invoice for the products THIS WARRANTY IS IN LIEU OF A...

Page 6: ...condensing I O Cards SENSOR or TRANSMITTER Part No Serial No Type of Gas Low Alarm Trip Point High Alarm Trip Point Note Refer to sensor module manual for additional specifications Note All Armstrong...

Page 7: ...this option is installed 8 HIGH ALARM INDICATOR High levels of gas are indicated by a red LED 9 LOW ALARM INDICATOR Low levels of gas are indicated by a yellow LED 10 TEST SWITCH The test switch is pr...

Page 8: ...urs 14 RELAYS There are two DPDT relays per channel which work with high alarm and low alarm respectively 15 TRANSFORMER Class II step down transformers run the internal circuitry at low voltages 16 S...

Page 9: ...G H ALARM P O W E R A I L F L O W H I G H ALARM AMC 1022 GAS MONITOR AMC 1022 GAS MONITOR 11 AUDIO ALARM INDICATOR 15 CLAMPS 4 HIGH ALARM INDICATOR 5 LOW ALARM INDICATOR 3 FAIL INDICATOR 2 POWER ON I...

Page 10: ...AMC 1022D Monitor 4 P C BOARD INDICATOR INDICATOR INDICATOR INDICATOR Figure 3 AMC 1022D monitor inside front panel...

Page 11: ...AMC 1022D Monitor 5 Figure 4 AMC 1022D monitor inside power relay panel...

Page 12: ...or operates on 120 VAC 60 Hz A class II step down transformer runs the internal circuitry at low voltages The power supply connections are made at the power terminal block located inside the monitor S...

Page 13: ...le sizes and lengths for monitor to sensor and sensor to sensor wiring refer to the Cable Selection And Wiring section in the AMC 122X series module manual s 4 0 DIMENSIONS IN INCHES 6 7 4 0 1 35 0 37...

Page 14: ...T POWER 120 VAC POSITIVE SIGNAL NEGATIVE S RED YELLOW BLACK SIG REMOTE AMC 122 X SERIES SENSOR MODULE SEE REMOTE AMC 122 X SERIES SENSOR MODULE MANUAL S FOR PROPER WIRING Figure 6 Monitor power connec...

Page 15: ...IL B N C B N O N O A N C A COIL COM A RELAY SOCKET CONNECTIONS RELAY DE ENERGIZED 7 13 5 9 3 5 1 1 8 14 COIL 6 12 COM 4 8 N O 2 4 N C 7 13 5 9 3 5 1 1 8 14 COIL 6 12 COM 4 8 N O 2 4 N C RELAY ENERGIZE...

Page 16: ...cuit miniature switch can be set accordingly Refer to Section 3 Item 14 and Figure 1 If any gas surrounding a sensor exceeds the low alarm trip point setting the yellow LED and low alarm relay will be...

Page 17: ...1022D Monitor 11 MULTIMETER DIGITAL CONNECT BLACK LEAD TO GND PAD P C BOARD HI LO ADJUST TRIMMERS MEASURE VOLTAGES AT HI LO TEST POINTS WITH RED LEAD Figure 8 Trimmer adjustments and test point locati...

Page 18: ...itions that could cause a liquid to enter the monitor and cause possible intrinsic damage to internal components 6 2 VERIFICATION OF OPERATION To verify the operation of the monitor and sensor module...

Page 19: ...R ON INDICATOR HIGH ALARM LOW ALARM HIGH LOW TERMINALS TRANSMITTER 17 5 16 8 0 37 1 0 10 0 1 0 0 37 OUTLINE OF P C BOARD SYSTEM CONFIGURATION ZONE No QUANTITY MODULES PART No TYPE OF GAS HOT NEUT GND...