![Ambient ACN-ML Manual Download Page 5](http://html.mh-extra.com/html/ambient/acn-ml/acn-ml_manual_2920297005.webp)
ACN-ML
Version 1.3 / 3.48
4. Powering
The ACN-ML can be powered by 5 to 24 Volts DC via either indicated Hirose 4-pin connectors, pin 1
carrying GND pin 4 positive voltage. The connectors are configured loop-through.
Only apply power
through one socket.
Upon applying external power the internal battery will automatically be charged.
The power source
must be capable of supplying 1.5A for charging the internal battery.
While in operation, the active power source is indicated in the upper right corner of the display,
EXT
means external power is applied with appropriate voltage and current, whereas
INT
indicates that the
unit is running on its integrated backup cell.
Typical values in operation with backup cell charged:
~ 500mA @ 5V DC
~ 220mA @ 12V DC
~ 120mA @ 24V DC
©Ambient Recording GmbH 2015
4