Console Operation 

Note: 

The  console  has  three  buttons  for  easy  operation: 

MIN/MAX/-

  button, 

SET

  button,  and

 

CH/+

 button. 

5.1 Min/Max Mode 

The Min/Max mode displays the minimum and maximum temperature and humidity (since reset of the 
unit) for the indoor, remote channel 1 through 8 sensors. 
 
Prior to entering the 

MIN/MAX 

mode, press the 

CH/+

 button to select the temperature and humidity 

values you wish to view. 
 

1.

 

Display  Maximum.  Press  the  MIN/MAX  button  once  to  display  the  maximum.  The 

 

icon will be displayed. 

2.

 

Clear  Maximum.

  To  reset  the  maximum  values  to  the  current  values,  press  and  hold  the 

MIN/MAX

 button for 3 seconds. 

3.

 

Display  Minimum.  Press  the  MIN/MAX  button again  to  display  the  minimum.  The

 

 

icon will be displayed. 

4.

 

Clear  Minimum.

  To  reset  the  minimum  values  to  the  current  values,  press  and  hold  the 

MIN/MAX

 button for 3 seconds. 

To return to normal mode, press the 

MIN/MAX

 button again. 

5.2 Clearing Min/Max Daily 

The  minimum  and  maximum  can  be  set  to  clear  daily  (every  24  hours  automatically)  or  manually. 

Press and hold the 

SET

 button for 3 seconds to switch between 

and Clears Manually. 

 
When you manually clear the minimum and maximum, the Clears Daily function will clear every 24 
hours from the time you clear it. 
 
For example, if you clear the min and max at 4:00pm, it will continue to clear every day at 4:00pm. 

5.3 Backlight Operation 

To temporarily turn on the back light for five seconds, press the 

any

 button on the indoor sensor. 

 

5.4 Indoor/Outdoor Channel Selection 

Press  the 

CH/+

  button  to  switch  the  display  between  the  indoor  temperature  and  humidity 

remote  sensors  1  through  8,  and  scroll  mode 

.  In  scroll  mode,  all  of  the  indoor  and  detected 

outdoor sensors will be displayed in five second intervals. 

5.5 Temperature Units of Measure 

The default temperature units of measure are degrees Fahrenheit. To toggle between degrees Celsius 
and degrees Fahrenheit, press and hold the 

MIN/MAX

 button for 3 seconds. 

5.6 Sensor Search Mode 

If any of the sensor communication is lost, dashes (--.-) will be displayed on the screen. To reacquire 
the signal: 

Summary of Contents for WS-0416

Page 1: ...tdoor Channel Selection 8 5 5 Temperature Units of Measure 8 5 6 Sensor Search Mode 8 5 7 Best Practices for Wireless Communication 9 5 8 Adjustment or Calibration 10 5 8 1 Humidity Calibration 10 5 8 2 Temperature Calibration 11 6 Glossary of Terms 11 7 Specifications 11 7 1 Wireless Specifications 11 7 2 Measurement Specifications 12 7 3 Power Consumption 12 8 Troubleshooting Guide 13 9 Accessor...

Page 2: ...HxW 4 3 x 2 5 x 0 65 LCD Dimensions LxW 2 1 x 1 7 LCD Segment Height 0 8 inches 1 Thermo hygrometer transmitter F007TH Dimensions LxHxW 4 5 x 2 0 x 0 75 1 User Manual 2 2 Recommend Tools Hammer and nail for hanging remote thermo hygrometer transmitter 2 3 Thermo Hygrometer Sensor Set Up Note Do not use rechargeable batteries We recommend fresh alkaline batteries for outdoor temperature ranges betw...

Page 3: ...he inside cover of the lid of the transmitter Figure 2 displays all four switches in the OFF position factory default setting Figure 2 3 Channel Number The WS0416 supports up to eight transmitters To set each channel number the default is Channel 1 change Dip Switches 1 2 and 3 as referenced in Table 1 4 Temperature Units of Measure To change the transmitter display units of measure F vs C change ...

Page 4: ...g the batteries the remote sensor LED indicator will light for 4 seconds and then flash once per 60 seconds thereafter Each time it flashes the sensor is transmitting data 7 Verify the correct channel number CH and temperature units of measure F vs C are on the display as shown in Figure 3 Figure 3 1 temperature 2 temperature units F vs C 3 channel number 4 relative humidity 8 Close the battery do...

Page 5: ...rature and humidity as designated by the icon The remote temperature and humidity will update on the display within a few minutes on the appropriate channel While in the search mode the remote search icon will be constantly displayed If you have more than one remote sensor up to eight remotes are supported the display will automatically toggle between sensors until all sensors have reported in Do ...

Page 6: ...14 Min Max Record mode 15 Indoor Icon 2 4 2 Sensor Operation Verification Verify the indoor and outdoor humidity match closely with the console and sensor array in the same location about 5 to 10 apart The sensors should be within 10 the accuracy is 5 Allow about 30 minutes for both sensors to stabilize The humidity can be adjusted or calibrated later to match each other a known source Verify the ...

Page 7: ...splay Features 4 1 Comfort Icon The comfort icon is based on humidity ranges specified in Figure 7 The icon is displayed for indoor humidity remote channel 1 humidity and optional remote channels 2 8 RH 45 RH 45 65 RH 65 Dry Comfortable Wet Figure 7 4 2 Rate of Change Icon The rate of change icon detects rapid changes in temperature and humidity If the arrow points upward the temperature is increa...

Page 8: ...5 2 Clearing Min Max Daily The minimum and maximum can be set to clear daily every 24 hours automatically or manually Press and hold the SET button for 3 seconds to switch between and Clears Manually When you manually clear the minimum and maximum the Clears Daily function will clear every 24 hours from the time you clear it For example if you clear the min and max at 4 00pm it will continue to cl...

Page 9: ...ices for trouble free wireless communication 1 Electro Magnetic Interference EMI Keep the console several feet away from computer monitors and TVs 2 Radio Frequency Interference RFI If you have other 433 MHz devices and communication is intermittent try turning off these other devices for troubleshooting purposes You may need to relocate the transmitters or receivers to avoid intermittent communic...

Page 10: ... to select the humidity sensor you wish to adjust To enter the humidity calibration mode press and hold the SET and MIN MAX buttons at the same time for 5 seconds and the humidity value will begin flashing Press the CH button to increase the humidity and the MIN MAX button to decrease the humidity reading in 1 increments To rapidly increase or decrease the humidity reading press and hold the CH or...

Page 11: ...alibrate temperature we recommend a mercury or red spirit fluid thermometer Bi metal dial and other digital thermometers are not a good source and have their own margin of error Using a local weather station in your area is also a poor source due to changes in location timing airport weather stations are only updated once per hour and possible calibration errors many official weather stations are ...

Page 12: ...0 to 90 1 Outdoor Humidity 10 to 99 5 only guaranteed between 20 to 90 1 7 3 Power Consumption Base station display console 2 x AAA 1 5V Alkaline or Lithium batteries not included Remote sensor 2 x AAA 1 5V Alkaline or Lithium batteries not included Battery life Minimum 12 months for base station with one sensor and excellent reception Intermittent reception Backlight often light and multiple sens...

Page 13: ...range is 300 and 100 under most conditions Move the sensor assembly closer to the display console If the sensor assembly is too close less than 5 move the sensor assembly away from the display console Make sure the remote sensor LCD display is working and the transmitter light is flashing once per 60 seconds Install a fresh set of batteries in the remote thermo hygrometer For cold weather environm...

Page 14: ...her F007TH Wireless Thermo Hygrometer for WS0416 Weather Stations Add additional remote thermo hygrometers Supports up to eight remote sensors Ambient Weather WS0416 C WS0416 Big Digit 8 Channel Wireless Thermo Hygrometer Console Only Add as many display consoles as you like to your existing system to display the remote sensor in different locations Ambient Weather SRS100LX Temperature and Humidit...

Page 15: ...ent has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfe...

Page 16: ...er s manual 3 damage resulting from the performance of repairs or alterations by someone other than an authorized Ambient LLC authorized service center 4 units used for other than home use 5 applications and uses that this product was not intended 6 the products inability to receive a signal due to any source of interference or metal obstructions and 7 extreme acts of nature such as lightning stri...

Reviews: