Cleaning, maintenance and repairs
12.11
Hydraulic system
WARNING
Risk of infection through the high pressure hydraulic fluid of the
hydraulic system entering the body!
•
Only a specialist workshop may carry out work on the hydraulic
system.
•
Depressurise the hydraulic system before carrying out work on
the hydraulic system.
•
When searching for leak points, always use suitable aids.
•
Never attempt to plug leaks in hydraulic hose lines using your
hand or fingers.
Escaping high pressure fluid (hydraulic fluid) may pass through
the skin and ingress into the body, causing serious injuries!
If you are injured by hydraulic fluid, contact a doctor immediate-
ly. Risk of infection!
WARNING
Danger of unintentional contact with hydraulic fluid!
Please take the following first-aid measures:
•
Following inhalation:
ο
No special action required.
•
Following contact with the skin:
ο
Wash off with plenty of soap and water.
•
Following contact with the eyes:
ο
Rinse eyes for several minutes under running water, hold-
ing the eyelid open.
•
Following ingestion:
ο
Seek medical assistance.