Use of the implement
UX01 Super CP Plus BAG0229.2 11.21
167
11.2.5 Spray agent suction from containers (closed transfer system)
1. Run the pump.
2. Couple the spray agent container with a
drip-free plug coupling.
3. TwinTerminal:
start the filling
procedure.
→
Spray agent suction from container.
4. TwinTerminal:
stop the filling
procedure when the desired quantity has
been drawn from the container.
Cleaning contaminated components:
5. Couple the flushing connection.
6. TwinTerminal:
start the cleaning
procedure.
→
Flush the components with water and
suction out the water.
7. TwinTerminal:
stop the cleaning
procedure.