Layout and function of the sprayer boom
114
UX01 Super CP Plus BAG0229.2 11.21
6.10.3 Drag hose equipment for Super-L boom (optional)
•
with metering discs for late top dressing with liquid fertiliser
(1) Drag hoses at 25 cm intervals, after fitting
the 2nd spray line.
(2) Bayonet connection with dosing discs.
(3) Metal weights - stabilise the position of the
hoses during operation.
(1) one setting tap for every boom part width
section:
a
Spraying via both spray lines with drag
hoses
b
Spraying via a standard spray line
c
Spraying via the 2nd spray line only
Remove drag hoses for normal
spraying operation.
After removing the drag hoses, seal off
the nozzle bodies with blanks
(1) Transport hooks
When working with drag hoses, the
two transport hooks must be screwed
on lower down. In transport position,
the distance between the nozzle and
the mudguard should be 20 cm!
For normal spraying operation, the two
transport hooks should be screwed
back on in the original position!