![Amazone UF 1201 Operating Manual Download Page 157](http://html1.mh-extra.com/html/amazone/uf-1201/uf-1201_operating-manual_2919803157.webp)
Using the machine
Driving to the field with the agitator switched on
1. Switch off spraying.
2. Switch on the universal joint shaft.
3. Set the desired stirring stage.
If this stirring stage differs from that required for spraying operation,
reset the stirring stage selected for the journey before commencing
spraying operation.
11.7.2
Drift reduction measures
•
Reschedule treatment for the early morning or the evening hours
(there is generally less wind).
•
Choose larger nozzles and a higher water spray rate.
•
Reduce spray pressure.
•
Precisely maintain the working height of the boom, because the
risk of drifting rises very sharply as the distance between the
nozzles increases.
•
Reduce operational speed (to below 8 km/h).
•
Use so-called anti-drift (AD) nozzles or injector (ID) nozzles
(nozzles which produce a high proportion of coarse drops).
•
Observe the distance requirements of the respective crop pro-
tection agent
11.7.3
Dilute the spray liquid with flushing water
1. Activate the pump, adjust pump speed to 450 rpm
2. Move switch tap
A
to position
.
3. Move switch tap
B
to position
.
4. Control the flushing water supply using the auxiliary agitator.
Once the desired amount of flushing water has been supplied::
5. Move switch tap
A
to position
.
UF BAG0012.11 04.19
157
Summary of Contents for UF 1201
Page 19: ...General safety instructions Super S boom Fig 4 Q Plus boom Fig 5 UF BAG0012 11 04 19 19 ...
Page 204: ...Liquid circuit 14 Liquid circuit single nozzle control 204 UF BAG0012 11 04 19 ...
Page 205: ...Liquid circuit Part width section control UF BAG0012 11 04 19 205 ...
Page 210: ...Spray table Fig 157 210 UF BAG0012 11 04 19 ...
Page 219: ...Spray table UF BAG0012 11 04 19 219 ...
Page 220: ......