![Amazone TSE 3000 Operating Manual Download Page 80](http://html1.mh-extra.com/html/amazone/tse-3000/tse-3000_operating-manual_2919778080.webp)
9.1.10 Checking the TwinTeC inner scraper
INTERVAL
100 operating hours
or
as required
The inner scraper is subject to wear. When the inside
of the concave discs is no longer sufficiently cleaned,
the inner scraper must be replaced.
1. Remove the hose
5
.
2. Remove the bolt
6
.
3. Remove the TwinTeC seed outlet
1
.
4. Replace the inner scraper
2
.
5. Install the bolt.
6.
To install the TwinTeC seed outlet,
place the guides
3
in the coulter bodies
4
.
7. Install the bolt.
8. Install the hose.
3
4
5
6
1
2
6 Nm
CMS-I-00003245
CMS-T-00004488-A.1
9 | Repairing the machine
Maintaining the machine
MG6860-EN-II | A.1 | 20.07.2020
76
Summary of Contents for TSE 3000
Page 1: ...Operating manual MG6860 EN II A 1 20 07 2020 seeding rail TSE 3000 Original operating manual...
Page 96: ......
Page 97: ......