![Amazone Precea 6000-2 Original Operating Manual Download Page 57](http://html1.mh-extra.com/html/amazone/precea-6000-2/precea-6000-2_original-operating-manual_2919775057.webp)
5.5 Coulters
5.5.1 PreTeC coulter
NOTE
The maximum placement depth serves as a
reference value. The actual value can only be
determined during field operation.
Coulter
Load
Coulter
pressure [kg]
Contact force
[kg]
Tare weight [kg]
Placement
depth [cm]
PreTeC coulter
Spring
100
/
120
0-10
PreTeC coulter in the
track
115
/
120
0-10
PreTeC coulter
Hydraulic
system
250
/
120
0-10
/
30-100
120
0-10
5.5.2 FerTeC Twin
NOTE
The maximum placement depth serves as a
reference value. The actual value can only be
determined during field operation.
Coulter
Load
Coulter pressure
[kg]
Tripping force
of the overload
safety [kg]
Placement depth
[cm]
FerTeC Twin
Spring
80
/
3 - 12
FerTeC Twin, coupled
Is adjusted via the PreTeC coulter.
200
3 - 12
5.6 Row spacings
NOTE
It is possible to subsequently convert the number
of rows. For more information, contact your
specialist workshop.
CMS-T-00005568-B.1
CMS-T-00005570-B.1
CMS-T-00005569-B.1
CMS-T-00005558-B.1
5 | Technical data
Coulters
MG6967-EN-II | C.1 | 27.09.2021