Hydraulic hose lines must not be more than 6 years
old.
3. Check the manufacturing date
1
.
CMS-I-00000532
4. Have any worn, damaged or aged hydraulic
hose lines immediately replaced at a specialist
workshop.
5. Retighten loose bolted connections.
9.1.18 Cleaning the fan rotor
INTERVAL
Every 50 operating hours
or
as required
The air drawn by the fan can contain fertiliser dust
or sand. These impurities can accumulate on the
fan rotors and cause imbalance of the fan. This can
destroy the fan.
REQUIREMENTS
The implement is coupled to the tractor
The singling unit housings are open
The singling discs are removed
1. Open the water drain
1
on the air distributor.
2.
To wash the deposits from the blower fan rotors,
Direct a jet of water into the suction opening
2
.
3.
When most of the water has escaped through
the air distributor,
run the fan for about 5 minutes.
The air supply is blown dry.
4. Switch off the fan.
5. Close the water drain on the air distributor.
1
2
CMS-I-00002024
CMS-T-00002390-B.1
9 | Repairing the machine
Maintaining the machine
MG6967-EN-II | C.1 | 27.09.2021
196