5.3 Permissible payload
Permissible payload =
Permissible technical implement weight according to
the rating plate - determined tare weight
= ––––––- kg
5.4 Metering unit
5.4.1 Seed metering unit
NOTE
The target spacing depends on the type of seed.
NOTE
With an electric drive, the target spacing can be
adjusted via the forward speed.
The minimum target spacing is based on the
maximum working speed, the maximum singling
unit speed, and the largest singling disc.
The maximum target spacing is based on the
minimum working speed, the minimum singling
unit speed, and the smallest singling disc.
Drive
Speed range
Target spacing
Electric drive
2 1/min to 55 1/min
3.8 cm to 49 cm
Mechanical drive, trailing
≤
55 1/min, depending on the
forward speed
4.6 cm to 37.7 cm
Mechanical drive, leading
≤
55 1/min, depending on the
forward speed
2.3 cm to 37.7 cm
Seed hopper
55 l/70 l
5.4.2 Fertiliser metering unit
NOTE
The maximum spread rate depends on the
metered material. The maximum spread rate is
based on a working speed of 15 km/h.
With an electric drive, the spread rate can be
adjusted via the forward speed.
CMS-T-00011018-A.1
CMS-T-00005918-B.1
CMS-T-00005919-B.1
CMS-T-00002362-E.1