1.
Park the implement on a horizontal surface.
2.
Loosen and remove the nut
1
.
3.
Remove the cover bolt
3
.
4.
Remove the cover with ventilation pipe
4
.
NOTE
If oil types are mixed, warranty claims cannot be
accepted.
Do not mix oils.
Fill with new and clean gear oil.
5.
If the spur gears
3
are not halfway covered
with transmission fluid in the spur gear trough,
refill oil according to the technical data.
6.
Check the fit of the gasket
2
.
7.
Install the cover with the ventilation pipe.
8.
Install the cover bolt.
9.
Install the nut
1
and tighten it.
NOTE
There is no need to change the oil in the spur
gear trough.
3
4
2
1
CMS-I-00003467
9.1.9 Changing the oil of the interchangeable wheel gear
INTERVAL
After the first 50 operating hours
Every 500 operating hours
ENVIRONMENTAL INFORMATION
Danger due to escaping oil
Collect any escaping oil.
Dispose of oil removal material in an
environmentally friendly manner.
CMS-T-00004631-A.1
9 | Repairing the machine
Maintaining the machine
MG6878-EN-II | D.1 | 18.05.2021
92
Summary of Contents for KE 3002
Page 1: ...Original operating manual Rotary harrow KE 3002 KE 4002 SmartLearning www amazone de ...
Page 6: ......
Page 119: ......