1.
Check the drawbar eye for damage, deformation,
cracks and wear.
2.
Have the damaged drawbar eye replaced by a
specialist workshop.
3.
Check the bolt tightening torques.
10.2 Cleaning the implement
IMPORTANT
Risk of machine damage due to cleaning
jet of the high-pressure nozzle
Never direct the cleaning jet of the
high-pressure cleaner or hot water
high-pressure cleaner onto the marked
components.
Never aim the cleaning jet of high-pressure
cleaners or hot water high-pressure
cleaners on electrical or electronic
components.
Never aim the cleaning jet of the high
pressure cleaner directly on lubrication
points, bearings, rating plates, warning
signs, and stickers.
Always maintain a minimum distance of
300 mm between the high-pressure nozzle
and the machine.
Do not exceed a water pressure of 120 bar.
CMS-I-00002692
Clean the machine with a high-pressure cleaner
or a hot water high-pressure cleaner.
CMS-T-00000593-E.1
10 | Repairing the implement
Cleaning the implement
MG7478-EN-GB | C.1 | 19.08.2022 | © AMAZONE
100