10.1.5 Replacing the C-Mix-3 Clip coulter
INTERVAL
as required
WARNING
Risk of crushing due to lowering of the
implement
Raise the implement only slightly.
1.
Release the coulter locking mechanism in the
direction shown by the arrow.
2.
Pull out the coulter locking mechanism.
3.
Use a hammer and the C-Mix-3 Clip assembly
iron to remove the C-Mix-3 Clip coulter tip.
4.
Put on the new C-Mix-3 Clip coulter tip.
5.
Hammer on the C-Mix-3 Clip coulter tip with a
hammer and the C-Mix-3 clip assembly iron.
6.
Slide in the coulter locking mechanism.
7.
Secure the coulter locking mechanism in the
direction of the arrow.
CMS-I-00003076
10.1.6 Replacing the discs
INTERVAL
as required
Original disc diameter
Wear limit
46 cm
36 cm
48 cm
40 cm
61 cm
43 cm
66 cm
46 cm
CMS-T-00004185-C.1
CMS-T-00002327-E.1
10 | Repairing the implement
Maintaining the implement
MG6806-EN-GB | Q.1 | 26.07.2022 | © AMAZONE
65
Summary of Contents for Cenio 3000
Page 83: ......