![Amazone Catros 4003-2TS Original Operating Manual Download Page 95](http://html1.mh-extra.com/html/amazone/catros-4003-2ts/catros-4003-2ts_original-operating-manual_2919720095.webp)
10.1.14 Checking the axle bolts
INTERVAL
Every 200 operating hours
or
Every 3 months
Check the bolts for tightness.
210 Nm
CMS-I-00003556
10.1.15 Checking the tyre inflation pressure
INTERVAL
as required
There are stickers attached in the rims of the wheels,
which specify the required tyre inflation pressure.
Check the tyre inflation pressure according to the
specifications on the stickers.
10.1.16 Checking the lower link hitch
INTERVAL
Every 50 operating hours
Lower link hitch
Wear dimension
Fixing bolts
Quantity
Bolt tightening
torques
Category 3
34.5 mm
M20 8.8
8
420 Nm
Category 4
48 mm
M20 8.8
8
420 Nm
Category 4N
48 mm
M20 8.8
8
420 Nm
Category K700
56 mm
M20 8.8
8
420 Nm
CMS-T-00004966-B.1