![Amazone Catros 2503 Special Operating Manual Download Page 63](http://html1.mh-extra.com/html/amazone/catros-2503-special/catros-2503-special_operating-manual_2919715063.webp)
Cleaning, maintenance and repairs
11.3
Replacing the discs (Workshop work)
Minimum disc diameter: 360 mm.
The discs are replaced with
•
the machine folded out
•
the discs raised
•
the machine secured against unintentional
lowering
1. Release the four screws securing the disc.
2. Remove the disc.
3. Secure the new disc with four screws.
CAUTION
When removing spring-suspended
elements (disc segments), remem-
ber that the parts are under preten-
sion! Use a suitable tool!
Use circlip pliers 78400609!
For installation and removal, addi-
tionally use longer screws as an
auxiliary tool! (1Fig. 3)
-
11.4
Roller
I
nspect the roller bearings for free movement at
regular intervals!
Check the bolts for tightness.
Required tightening torque: 210 Nm.
To connect the rollers correctly, the
clamping bracket and its bolts must be
installed according to picture.
Catros BAG0160.4 02.19
63
Summary of Contents for Catros 2503 Special
Page 70: ...G ...