9.3.6 The coulter harrow does not cover the seed sufficiently with fine soil
The harrow tines of the coulter harrow are worn.
1.
Remove the nut
1
.
2.
Remove the bolt
4
.
3.
Remove the harrow bracket
2
.
4.
Replace the harrow tines
3
.
5.
Move the harrow bracket to the desired position.
6.
Install the bolt.
7.
Install the nut and tighten it.
8.
To check the setting,
seed for approx. 30 m at working speed and then
check the work pattern.
CMS-I-00004632
9.3.7 The RoTeC coulter is not spreading seed
The seed outlet is strongly blocked.
1.
If the blockage cannot be removed from below,
Remove the conveyor hose
2
.
2.
Clean the seed outlet
1
from above.
3.
Install the conveyor hose.
CMS-I-00004767
CMS-T-00006604-A.1
CMS-T-00006606-A.1
9 | Repairing the machine
Eliminating faults
MG6545-EN-II | B.1 | 22.07.2021