25
gB
Hold both keys simultaneously for approx. 3 sec.
- Press the key until OP.U appears.
Confirm the mode.
User mode: parameters can no longer be
changed (locked).
_ Hold the respective arrow keys
&
to reach the
desired parameter value faster. As a result,
the values are changed according to the decimal
numbering scheme (after 10 counting units,
the respective preceding value is changed).
MaIntenance/care
_ Wipe the upper surface of the furnace with a
moist cloth when necessary. In no event must
water enter the inside of the chamber! Do not
clean with organic solvents.
_ Regular maintenance/calibration of the heating
elements and insulation is not necessary. A
visual check of the heating elements before
starting the sintering program is recommended!
exchanging the heating elements
_ If the indicator lamp of the heating
@
shines
continuously after the start-up of the sintering
program, this means that the heating element
has failed.
_ If one heating element fails, always replace
all 3 elements! If a heating element should fail
again, the heating elements already used can
be fitted again.
general instructions
_ During the installation of the heating elements
in the furnace, a small amount of refractory
material may adhere to the heating elements;
this is harmless and will vitrify during the first
few sintering processes.
_ Lamp test: in case not all of the two LEDs
(
*
+
(
) and displays (
#
+
$
) flash up, the lamps
are defective; please contact the customer
service.
_ If many coloured objects are sintered, it is
recommended to occasionally run a sintering
programme with empty furnace.
_ Each furnace runs through one programme