RHA60B2A
Remote Heat Pump
NOTE: It is important to electrically connect the unit and
properly size fuses/circuit breakers and wires in accor-
dance with all national and/or local electrical codes. Use
copper wire only.
Specification Sheet
Due to policy of continual product improvement, the right
is reserved to change specifications and design without
notice.
Standard Features
• Bi-Flow Liquid Line Drier (Shipped Loose)
• Front Seating Valves
• 5 Minute Anti-Short Cycle Protection
• Time-Temperature Defrost System
• Low RPM (825) Condenser Fan
• Scroll Compressor
• Accumulator
Accessories
• Pressure Control Kit (PCK02A)
Automatic Reset High Pressure Switch
Time Delay
• Fossil Fuel Kit (FFK03A)
• Compressor Sound Blanket (CSB09A)
• Ambient Temperature Kit (ATK05)
• Low Ambient Control (LAC03A)
Unit is rated for 1 1/8” suction line. Factory connection is
7/8”. Installer will need to supply 7/8” to 1 1/8” adapters for
suction line connections. When mixing and matching
restrictor orifice indoor coils, use restrictor orifice part
number B1443827 or 11076323, 0.090” diameter.
NOTE: Defrost control compressor run time is factory set
at 90 minutes.
Heat Pump Performance Data
For ARI Performance Data: See the ARI Directory, Product Data Booklet (PDB), or the product Service Manual.
June 1998
20209807
Above information is for nominal CFM and 70° F indoor dry bulb.
All pressures are PSIG. All temperatures are °F.
Amps are outdoor unit amps.
Low pressure is measured at the gauge port. High pressure is measured at the liquid service valve.
A higher standard of comfort
Heating
¡
Air Conditioning
®
Amana
Fayetteville, TN 37334
Outdoor Ambient Temperature (° F)
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
∆
T
34
32
31
29
27
26
25
23
22
20
18
17
17
15
13
12
10
8
Amps
23.6 21.9 20.4 19.2 18.5 18.1 17.1 16.2 15.5 14.8 14.1 13.7 13.5 12.8 11.9 11.2 10.3
9.3
HI PR
252
241
232
222
217
212
204
196
188
179
172
168
165
159
153
146
141
136
LO PR
69
64
60
55
52
50
46
41
37
33
29
27
26
22
19
16
14
11
RHA60B2A / BBA60A2A / CCA60FCC
Specifications
Cooling Capacity, BTUH (Nominal)
60,000
Compressor
R.L. Amps
28.8
L.R. Amps
169
Condenser Fan Motor
Horsepower
1/4
R.L. Amps
1.7
L.R. Amps
3.3
Liquid Line, Inches O.D.
3/8
Suction Line, Inches O.D.
1 1/8
Refrigerant Charge (oz)
167
Power Supply
208/230-60-1
Min Circuit Ampacity
37.7
Max Overcurrent Device
60
Electric Conduit Size (in)
Power Supply
1/2 or 3/4
Low Voltage
1/2
Approximate Shipping Weight (Lbs)