background image

RHA60B2A

Remote Heat Pump

NOTE: It is important to electrically connect the unit and
properly size fuses/circuit breakers and wires in accor-
dance with all national and/or local electrical codes. Use
copper wire only.

Specification Sheet

Due to policy of continual product improvement, the right
is reserved to change specifications and design without
notice.

Standard Features

• Bi-Flow Liquid Line Drier (Shipped Loose)
• Front Seating Valves
• 5 Minute Anti-Short Cycle Protection
• Time-Temperature Defrost System
• Low RPM (825) Condenser Fan
• Scroll Compressor
• Accumulator

Accessories

• Pressure Control Kit (PCK02A)

Automatic Reset High Pressure Switch
Time Delay

• Fossil Fuel Kit (FFK03A)
• Compressor Sound Blanket (CSB09A)
• Ambient Temperature Kit (ATK05)
• Low Ambient Control (LAC03A)

Unit is rated for 1 1/8” suction line.  Factory connection is
7/8”.  Installer will need to supply 7/8” to 1 1/8” adapters for
suction line connections.   When mixing and matching
restrictor orifice indoor coils, use restrictor orifice part
number B1443827 or 11076323, 0.090” diameter.

NOTE: Defrost control compressor run time is factory set
at 90 minutes.

Heat Pump Performance Data

For ARI Performance Data: See the ARI Directory, Product Data Booklet (PDB), or the product Service Manual.

June 1998

20209807

Above information is for nominal CFM and 70° F indoor dry bulb.

All pressures are PSIG.  All temperatures are °F.

Amps are outdoor unit amps.

Low pressure is measured at the gauge port.  High pressure is measured at the liquid service valve.

A higher standard of comfort

Heating 

¡

 Air Conditioning

®

Amana

Fayetteville, TN 37334

Outdoor Ambient Temperature (° F)

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

T

34

32

31

29

27

26

25

23

22

20

18

17

17

15

13

12

10

8

Amps

23.6 21.9 20.4 19.2 18.5 18.1 17.1 16.2 15.5 14.8 14.1 13.7 13.5 12.8 11.9 11.2 10.3

9.3

HI PR

252

241

232

222

217

212

204

196

188

179

172

168

165

159

153

146

141

136

LO PR

69

64

60

55

52

50

46

41

37

33

29

27

26

22

19

16

14

11

RHA60B2A / BBA60A2A / CCA60FCC

Specifications

Cooling Capacity, BTUH (Nominal)

60,000

Compressor

 

R.L. Amps

28.8

L.R. Amps

169

Condenser Fan Motor

Horsepower

1/4

R.L. Amps

1.7

L.R. Amps

3.3

Liquid Line, Inches O.D. 

3/8

Suction Line, Inches O.D. 

1 1/8

Refrigerant Charge (oz)

167

Power Supply

208/230-60-1

Min Circuit Ampacity

37.7

Max Overcurrent Device

60

Electric Conduit Size (in)

Power Supply

1/2 or 3/4

Low Voltage

1/2

Approximate Shipping Weight (Lbs)

180

Reviews: