Amana MBVC Series Wiring Diagram Download Page 1

SS-AMBVC

www.amana-hac.com

11/09

Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.

MBVC

V

ariaBle

-S

peed

, C

oMfort

N

et

-

C

oMpatiBle

 M

odular

 B

lowerS

C

ooliNg

 C

apaCity

18,000 - 60,000 Btu/

h

Standard Features

•  ComfortNet™ Communications System compatible
•  Variable-speed ECM blower motor
•  Auto configuration of the airflow and tonnage  

in communicating mode

•  CFM indicator
•  Maximum four low-voltage wires required for  

operation in communicating mode

•  Built-in dehumidify feature
•  Diagnostic indicator lights
•  Storage of six prior fault codes
•  Programmable heat strip settings
•  Color-coded terminal strip for non- 

communicating set-up

•  Cooling and heat pump applications
•  AHRI Certified; ETL Listed

Cabinet Features

•  Painted, galvanized-steel cabinet
•  Blower section usable as an electric furnace
•  Foil-faced insulation is glued in place and covers entire 

blower case, reducing sound and cabinet condensation

•  Bottom flanges formed inward for additional strength,  

and to provide mounting surface for cased-coil section

* Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the 
10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. 
Online registration is not required in California or Québec. 

Summary of Contents for MBVC Series

Page 1: ...ghts Storage of six prior fault codes Programmable heat strip settings Color coded terminal strip for non communicating set up Cooling and heat pump applications AHRI Certified ETL Listed Cabinet Feat...

Page 2: ...ower 1 208 230 60 1 Motor Speed Revisions V Variable Speed A First Series C ComfortNet Compatible Circuit Breaker Airflow Delivered A No Circuit Breaker 08 800 CFM B Circuit Breaker 12 1200 CFM 16 160...

Page 3: ...208 230 1 4 3 15 10 8 73 MBVC1600AA 1 1 600 to 1 000 208 230 1 6 3 15 10 8 83 MBVC2000AA 1 2 000 to 1 200 208 230 1 5 8 15 11 10 95 Minimum Circuit Ampacity MCA and Maximum Overcurrent Protection MOP...

Page 4: ...menu in the CTK01AA T STAT Cooling HP Airflow S1 S2 Speed Tap MBVC1200 Airflow SCFM MBVC1600 Airflow SCFM MBVC2000 Airflow SCFM off off A 600 1000 1200 on off B 800 1200 1600 off on C 1000 1400 1800 o...

Page 5: ...6 500 11 029 11 209 20 021 13 178 11 209 23 464 813 16 103 16 16 133 16 11 23 17 21 24 11 11 201 16 Side and Front Views W H 3 KNOCKOUTS 1 125 1 375 1 750 875 KNOCKOUT 2 PLACES C 6 1 2 5 5 1 8 3 1 4 D...

Page 6: ...Typical Two Stage Cool Two Stage Heat Thermostat Dehumidistat Optional G W1 W2 Y1 Y2 O Y2 W1 W2 Y1 Y2 Remote Condensing Unit Two Stage AC NEU HOT DEHUM C R G R Y1 1 2 R C C Modular Blower Integrated...

Page 7: ...AGE INTEGRATED CONTROL MODULE TX 3 DEHUM C W1 1 5 FIELD SPLICE W1 CFM LED R Y1 NOTES LOW VOLTAGE 24V 4 GND W1 24 V 3 A 4 RX 2 COLOR CODES Y2 TH STATUS LED 5 TO RECALL THE LAST 6 FAULTS MOST RECENT TO...

Page 8: ...f Maytag Corporation or its related companies and used under license to Goodman Company L P All rights reserved Our continuing commit ment to quality products may mean a change in specifications witho...