background image

Description

This kit is used to control condensate from the unit.  Conden-
sate water drains from the chassis into the sleeve during
normal heat pump operation and during times of high
humidity when the unit is in cooling operation. The drain kit
allows the condensate from the outdoor and indoor coils to
be routed to a suitable area.  It can be installed for either
outdoor or indoor use. For outdoor use, the condensate can
be drained from either the right- or left-hand side of the wall
sleeve.  Local codes will determine the proper condensate
disposal.  For indoor use, the drain components must be
installed on the bottom of the wall sleeve and connected to
a drain system inside the building.

NOTE:

  This drain kit serves only as a link between the unit

and field-supplied condensate drain system.  Installing the
kit without connecting it to a drainage system will result in
inadequate condensate removal, possible leakage and
corrosion.

ALGAECIDE:

  Most algaecide products will cause damage

to the unit basepan or coils and should not be used.  Contact
your sales representative for the recommended algaecide
pan treatment for your unit.

Part No. A3494906 (1)

The installation and servicing of the equipment should be done by

qualified experienced technicians.

The drain components for outdoor use must be installed
before the wall sleeve condenser grille.

1. Remove the rear enclosure panel and the sleeve stiff-

ener.  These items can be removed from the inside of

the building.

2. Insert the 1/2” drain fitting in the opening of the outdoor

drain fitting gasket and plate. Secure this assembly into

the holes located on the rear of the wall sleeve  using

two of the outdoor mounting screws provided.

3. Place the remaining outdoor gasket on the outside

blank-off plate and secure the assembly to the left rear

of wall sleeve with the two mounting screws provided.

Unit chassis installed immediately

Install the condenser grille to wall sleeve with hardware
provided.  See condenser grille installation instructions.

Unit chassis installed later

Replace the rear enclosure panel in the wall sleeve to
protect the inside of the building from weather damage.

1/2" Drain Fitting

Outdoor

Drain Fitting

Plate

Outdoor Drain

Fitting Gasket

 

Outdoor Drain Fitting

Left Blank-Off

Drain

Fitting

Indoor

Drain Fitting

Gasket

Indoor

Drain Fitting

Plate

Outdoor

Mtg. Screws

Qty: 4

Indoor

Mtg. Screws

Qty: 2

Outdoor

Drain Fitting

Plate

Outdoor

Drain Fitting

Gasket

Qty: 2

Outdoor

Blank-Off Plate

Drain Kit Components

Installation for Outdoor Use

PTAC

COMBINATION DRAIN KIT (DK9001D)

I

NSTALLATION

 I

NSTRUCTIONS

For outdoor or indoor 

 sleeve drainage

September 2003

NOTE

USE ONLY  WS900

B

 WALL SLEEVES WITH DK9001D.

DO 

NOT

 INSTALL THIS DRAIN KIT ON WS900

D

 WALL

SLEEVES!

Reviews: