background image

6" (15.2 cm) vent system = 73 ft (22.2 m) total

A. Two 90° elbows = 20 ft (6.1 m)
B. 1 wall cap = 40 ft (12.2 m)

C. 1 rectangular to round transition piece = 5 ft (1.5 m)
D. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)

A                                                                  B 

C                                  D 

6 ft (1.8 m) 

2 ft 

(0.6 m) 

29

⁷⁄₈

" (76.0 cm)

15

³⁄₄

"

(40.

0 cm)

17

¹⁄₄

"

(43.8 cm)

16

¹⁄₄

"

(41.3 cm)

PRODUCT MODEL NUMBERS

PRODUCT DIMENSIONS

VENTING REQUIREMENTS

AMV1160VA

AMV2174VA

Electrical:

A 120-volt, 60-Hz, AC-only, 15- or 20-amp fused electrical

supply with a fuse or circuit breaker. A time-delay fuse or time-delay circuit
breaker is recommended. It is recommended that a separate circuit serving
only this microwave oven be provided.

Microwave Hood Combination

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. W10191951

09-15-08

CABINET OPENING DIMENSIONS

A 3

¹⁄₄

" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should be used.

The total length of the vent system including straight vent, elbow(s), transitions and wall
or roof caps must not exceed the equivalent of 140 ft (42.7 m) for either type of vent. 
For best performance, use no more than three 90° elbows.
To calculate the length of the system you need, add the equivalent length for each vent
piece used in the system. See the following examples:

The grounded 3 prong outlet must be inside the upper cabinet. 

*30" (76.2 cm) is typical for 66" (167.6 cm) installation height. 

Exact dimensions may vary depending on type of range/cooktop 
below.

A. 2" x 4" wall stud
B. Grounded 3-prong outlet

66" (167.6 cm) min.

12" (30.5 cm) min.
14" (35.6 cm) max.

A                            B

30" (76.2 cm) typical*

30"

(76.2 cm)

min.

A. Rectangular to round transition piece: 3

¹⁄₄

" x 10" to 6" = 5 ft

(8.3 x 25.4 cm to 15.2 cm = 1.5 m)

B. Roof cap: 3

¹⁄₄

" x 10" = 24 ft (8.3 x 25.4 cm = 7.3 m)

C. 90° elbow: 3 " x 10" = 25 ft (8.3 x 25.4 cm = 7.6 m)
D. 90° elbow: 6" = 10 ft (15.2 cm = 3 m)

E. Wall cap: 3

¹⁄₄

" x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m)

F. 45° elbow: 6" = 5 ft (15.2 cm = 1.5 m)

G. 90° flat elbow: 3

¹⁄₄

" x 10" = 10 ft (8.3 x 25.4 cm = 3 m)

A                           B                            C 

D                  E                    F               G

3

¹⁄₄

" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total

A. One 3

¹⁄₄

" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)

B. 1 wall cap = 40 ft (12.2 m)
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)

A                                          B

C

6 ft (1.8 m)

2 ft

(0.6 m)

Rectangular to Round Transition for Roof Venting

NOTE:

 The minimum 3" (7.6 cm) clearance must exist between 

the top of the microwave oven and the rectangular to round 
transition piece so that the damper can open freely and fully.

A

B

C

E

F

D

3" (7.6 cm)

A. Roof cap
B. 6" (15.2 cm) min. diameter round vent

C. Elbow (for wall venting only)
D. Wall cap

E. 3

¹⁄₄

" x 10" to 6" (8.3 x 25.4 cm to 15.2 cm) 

rectangular to round transition piece

F. Vent extension piece, at least 3" (7.6 cm) high

®

Reviews: