ELECTRICAL SHOCK HAZARD

 – Turn off power at the main service panel by removing 

the fuse or switching the appropriate circuit breaker to the OFF position before 
removing the existing thermostat.

1.  Turn off power to the heating and cooling system by removing the fuse or switching the 

appropriate circuit breaker off.

2.  Remove cover of old thermostat. This should expose the wires.
3.  Label the existing wires with the enclosed wire labels before removing wires.
4.  After labeling wires, remove wires from wire terminals.
5.  Remove existing thermostat base from wall.
6.  Refer to the following section for instructions on how to install this thermostat.

To Remove Existing Thermostat

Specifications

Electrical rating:

  • 24 VAC (18-30 VAC) 

 

 

• 4 amp maximum total load

 

• 1 amp maximum per terminal

Temperature control range: 

45°F to 90°F (7°C to 32°C)   

Accuracy:

 ± 1°F (± 0.5°C)

System configurations:

 2-stage heat & 1-stage cool heat pump, 1-stage electric heat

Timing:

 

Anti-short Cycle: 4 minutes

 

Backlight Operation: 10 seconds

Terminations:

 R, C, O/B, Y, W, GH, GL

Important Safety Information

WARNING!

Always turn off power at the main power supply before installing, cleaning, 
or removing thermostat.

• This thermostat is for 24 VAC applications only; do not use on voltages over 30 VAC
• All wiring must conform to local and national electrical and building codes
• Do not use air conditioning when the outdoor temperature is below 50 degrees; this can damage 

your A/C system and cause personal injuries

• Use this thermostat only as described in this manual

Package Contents/Tools Required

Package includes:

 

Amana

®

 2246003

 thermostat on base, thermostat cover, wiring labels, screws 

and wall anchors, Installation, Operation and Application Guide

Tools required for installation:

 Drill with 3/16” bit, hammer, screwdriver

Installation, Operation & 

Application Guide

www.amana-ptac.com

2246003

Non-Programmable Electronic Thermostat

Electric Heat or HP, Manual Changeover, Hardwired

•  Configurable
•  2-Stage Heat Pump Systems
•  1-Stage Electric Heat
•  Backlit Display
•  Field Calibration Feature
•  Relay Outputs  

(minimum voltage drop in thermostat)

•  Ideally Suited for: 

– 

Residential (New Construction/Replacement) 

– 

Light Commercial

Parts Diagram

RESET

LEFT

RIGHT

Fan Switch

Mode Switch

Left

Button

Right

Button

Reset Switch

Large Backlit Display

Up Button

Down Button

ELECTRICAL SHOCK HAZARD

 – Turn off power at the main service panel by removing 

the fuse or switching the appropriate circuit breaker to the OFF position before 
removing the existing thermostat.

 

IMPORTANT:

  Thermostat installation must conform to local and national building and 

electrical codes and ordinances. 

 

 

Note:

 

Mount the thermostat about four feet above the floor. Do not mount the thermostat 
on an outside wall, in direct sunlight, behind a door, or in an area affected by a vent 
or duct.

1. Turn off power to the heating and cooling system by removing the fuse or switching the appropriate 

circuit breaker off.

2.  To remove cover, insert and twist a coin or screwdriver in the slots on top of the thermostat.
3.  Put thermostat base against the wall where you plan to mount it (Be sure wires will feed through 

the wire opening in the base of the thermostat).

4.  Mark the placement of the mounting holes.
5.  Set thermostat base and cover away from working area.
6.  Using a 3/16” drill bit, drill holes in the places you have marked for mounting.
7.  Use a hammer to tap supplied anchors in mounting holes.
8.  Align thermostat base with mounting holes and feed the control wires through wire opening.
9.  Use supplied screws to mount thermostat base to wall.
10. Insert stripped, labeled wires in matching wire terminals. See “Wiring Diagrams” section of this 

manual.

 

CAUTION!

Be sure exposed portion of wires does not touch other wires.

11.  Gently tug wire to be sure of proper connection. Double check that each wire is connected to the 

proper terminal. 

12. Seal hole for wires behind thermostat with non-flammable insulation or putty.
13. Replace cover on thermostat by snapping it in place.
14. Turn on power to the system at the main service panel.
15. Test thermostat operation as described in “Testing the Thermostat”.

To Install Thermostat

Terminal Designator Descriptions

 

R  –  24 VAC hot

 

C  –  24 VAC common

  O/B  –  Reversing valve
 

Y  –  1st stage cool, 1st stage HP heat for HP

  W  –  2nd stage heat for HP, 1st stage electric heat
  GH  –  Fan High
  GL  –  Fan Low

Wiring Diagram Conversions

Cool & Electric Heat

Heat Pump

Output Chart

1

ST

 Cool

1

ST

 Heat

2

ND

 Heat

HSo = Heat Pump (cool active reversing valve)

Y, GL, O

Y, GL

Y, GL, W

HSb = Heat Pump (heat active reversing valve)

Y, GL

Y, GL, B

Y, GL, B, W

HSE = Electric Heat

Y, GL

W, GL

W, GL

 

Note:

 

GL will be on during heating and cooling cycle when fan switch is set to 

Auto

Fan High

Fan Low

Heat

Compressor

X

Former

Reversing Valve

Auxiliary Heat

Compressor

Fan High

Fan Low

X

Former

Reviews: