![AMALGAMATED INSTRUMENT LD5-RS Operation And Instruction Manual Download Page 61](http://html1.mh-extra.com/html/amalgamated-instrument/ld5-rs/ld5-rs_operation-and-instruction-manual_2915959061.webp)
5.96
Auto display brightness low level
Section:
dISP
Display:
Auto Lo
Range:
1
to
64
Default Value:
7
Default Access Level
2
Function number
22Eb
Automatic brightness low level - seen only when
brgt Auto
is set to
ON
. The low brightness level sets the
minimum brightness which the automatic brightness control can achieve with
64
being the highest intensity and
0
being the lowest intensity.
5.97
Serial comms. operation mode
Section:
SErI
Display:
OPEr
Range:
NONE
,
Cont
,
PoII
,
A.buS
,
diSP
,
M.buS
Default Value:
NONE
Default Access Level
4
Function number
4480
Allows selection of the operating mode to be used for RS232 or RS485 serial output communications. See the
“LD5/LE5 Series Large Digit Display Output Addendum” for more information and wiring details of optional
isolated serial communications.
Choices are:
•
NonE
- no serial comms. required.
•
Cont
- sends ASCII form of display data at a rate typically 90% of the sample rate.
•
PoII
- controlled by computer or PLC etc. as host. The host sends command via RS232/485 and instrument
responds as requested.
•
A.buS
- this is a special communications mode used with Windows compatible PC download software. This
mode must be used if communications via USB is used. Refer to the user manual supplied with this optional
software.
•
dISP
- sends image data from the display without conversion to ASCII. This mode should only be used
when the serial output is connected to another display from the same manufacturer.
•
M.buS
- Modbus RTU (RS232/RS485) is used. See
CONF CodE
function for further description.
•
ChAn
- not currently applicable to this instrument.
5.98
Serial baud rate
Section:
SErI
Display:
bAud
Range:
1200
,
2400
,
4800
,
9600
,
19.2
,
38.4
,
57.6
,
115.2
Default Value:
9600
Default Access Level
4
Function number
4484
Allows the baud rate to be set for serial communications. Choices are:
LD5RSMAN-2.0-0