80
ML-7 Series/ML-9001A
Troubleshooting
If any problems occur with the equipment during the self-diagnostic at power-on, error details are
displayed on the control panel.
Refer to the following error message list when troubleshooting problems.
A.1 Error Messages on the Operating Unit
Item
Error Details
Cause and Corrective Action
Checking
ROM
SRAM Error
There is a problem with the controller.
If the error persists after restarting, contact us.
Checking
RAM
Font Error
Memory capacity has been reached when attempting to register the font, the
file size of font is 0, or the font may be unsupported.
Connect the LMDraw to check the registration of the font (1st/2nd standard
fonts, cursive text, or kanji).
Variable Error
Memory capacity has been reached when attempting to store a variable or
number, or the variable number may be unsupported.
Connect the LMDraw to check variable registration.
Part Error
Memory capacity has been reached when attempting to register a part, the
file size of part is 0, or the part may be unsupported.
Connect the LMDraw to check part registration.
Layout Error
Memory capacity has been reached when attempting to register a layout file,
the file size of layout is 0, or the layout file may be unsupported.
Connect the LMDraw to check the layout file registration.
Serial Error
Memory capacity has been reached when attempting to store a serial
number, or the serial number may be unsupported.
Connect the LMDraw to check serial registration.
Date Error
Memory capacity has been reached when attempting to store a calendar
setting, or the calendar setting may be unsupported.
Connect the LMDraw to check calendar setting.
Appendix
A
Summary of Contents for ML-7 Series
Page 4: ......
Page 8: ...4 ML 7 Series ML 9001A Contents...
Page 82: ...Chapter 4 78 ML 7 Series ML 9001A Chapter 4 Maintenance...