70
ML-3030AS/3015AS
3 . Changing the Equipment Settings
LASER CONTROL OPTION PARAMETERS
How to see the displayed items
: Settable item
LD AUTO
START
Sets the LD to ON or OFF. At ON, a LD becomes ON at AUTO START and the
screen is displayed in the status of LD: ON.
NG LASER
STOP
At ON, a laser stops when error No.035/LASER POWER OUT OF RANGE occurs.
LASER
START
DELAY
Sets the acceptance time for laser start signal and schedule signal from 0.1 ms, 1
ms, 2 ms, 4 ms, 8 ms, or 16 ms.
GUIDE
BLINK
Sets the guide light blinking status or continuous lighting to ON or OFF.
EXT-IO
PULSE
WIDTH
Sets the output time for end signal and monitor normal/trouble signal from 20 ms, 30
ms, or 40 ms.
CW SLOPE
CHK
DISABLE
Sets the slope portion to be monitored or not in the CW envelope monitoring
(monitoring laser in range). At ON, the slope portion is not monitored.
X
Returns to the CONFIG screen.