2 . Checking the Equipment Status
61
ML-3030AS/3015AS
Chapter 2 V
arious Settings
Introduction Part
Inst
allat
ion and
Preparation Part
Operating Part
Maintenance Part
Appendixes
2 . Checking the Equipment Status
STATUS Screen
On the STATUS screen, the laser control method, the laser light sharing specification,
and the total number of laser light outputs can be checked. In addition, the error log,
event log, and software version can be checked.
How to see the displayed items
: Settable item
CONTROL
DEVICE
Displays the used laser control method.
EXTERNAL CONTROL (external control):
Control is exerted by the PLC connected to the EXT. I/O connector.
PANEL CONTROL (internal control):
Control is exerted by control panel.
RS-485 CONTROL (external communication control):
Control is exerted by the personal computer connected to the RS-485 (1)
or RS-485 (2) connector.
DELIVERY
SYSTEM
Displays the laser light sharing method such as single delivery, powersharing,
and timesharing.
SHOT COUNT
GOOD COUNT
Resets the displayed total number of laser light outputs (SHOT COUNT).
Resets the displayed appropriate number of laser light outputs (GOOD COUNT).
Pressing the RESET button resets the value to 0.
LD WORK
TIME
Displays the total time of LD.
FLASH WORK
TIME
Displays the laser output time.
Laser Unit Temp .
Displays the temperature of each laser unit in the equipment.
Ext . I/O
Displays the TERMINAL MONITOR screen. Then, the external input/output
monitor is displayed.
ERROR LOG
Displays the ERROR LOG screen. Then, the error history is displayed.
EVENT LOG
Displays the EVENT LOG screen. Then, the event history is displayed.
Summary of Contents for ML-3015AS
Page 21: ...Introduction Part...
Page 22: ......
Page 30: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 52: ......
Page 53: ...Operating Part...
Page 54: ......
Page 163: ...Maintenance Part...
Page 164: ......
Page 175: ...Appendixes...
Page 176: ......