44
ML-3030AS/3015AS
2 . Connecting the Optical Fiber
2 . Connecting the Optical Fiber
This section explains the
method of connecting the optical fiber on the laser
beam output unit side .
WARNING
■
Be sure to receive education for this work from our engineer .
■
Before starting work, be sure to turn OFF the power supply .
⇒
Do not disconnect the optical fiber on the laser beam input unit side. When dis
-
connecting it, contact us for information.
Models other than ML-30□□AS-110
Precautions during Operation
⇒
During operation, wear fingerstalls or gloves (power free).
⇒
During operation, take care not to give shocks to the optical fiber or bend it below
the minimum bending radius (in the following table).
Minimum bending radius of the optical fiber
Core Diameter
Minimum Bending Radius
φ 0.1, 0.2, 0.3, 0.4 mm
100 mm
φ 0.6 mm
150 mm
φ 0.8 mm
200 mm
Item required
Fingerstalls or gloves (power free), air blow (gas type), end face checker, lens clean-
ing paper, HYPERCLEAN (EE-3310), lighting, and clean booth
1
Cleaning the End Face of the Optical Fiber
(1) Loosen the set screw (M3) on the output unit side to remove the cable gland and
the cylinder, and then pass the optical fiber through them.