1 . Connecting the Power Supply
43
ML-3030AS/3015AS
Chapter 2 Connections and Preparations of Each Section
Introduction Part
Inst
allat
ion and
Preparation Part
Operating Part
Maintenance Part
Appendixes
Chapter 2
●
Connections and Preparations of
Each Section
1 . Connecting the Power Supply
CAUTION
Your qualified electrician must carry out the electrical connection to main power
supply . (Also follow your local accident prevention regulations, such as the German
Regulation, BGVA2 .)
CAUTION
For the power supply side, we earnestly recommend using a leakage breaker with
the rated current of 15 A or more, which is applicable to harmonics and surges .
Item required
Slotted screwdriver and Phillips screwdriver
Operating Procedure
(1) Open the connector cover on the rear.
(2) Loosen the cable gland on the connector cover to pass the power harness.
(3) While confirming the terminal colors of the power harness, connect the power
harness to the L (white), N (black), and PE (green) power input terminals, and
secure it with screws.
(4) Install the connector cover.
(5) Tighten the cable gland to secure the harness.
Installation and
Preparation Part
When the connector
cover is open
Power input
terminals
L N PE
White
Black
Green
5 .5 sq
Ferrule terminal
for 5 .5 sq
Summary of Contents for ML-3015AS
Page 21: ...Introduction Part...
Page 22: ......
Page 30: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 52: ......
Page 53: ...Operating Part...
Page 54: ......
Page 163: ...Maintenance Part...
Page 164: ......
Page 175: ...Appendixes...
Page 176: ......