194
ML-3030AS/3015AS
Output Schedule Data Entry Table
NETWORK #
Output Schedule Data Entry Table
Output Schedule Data Entry T
able [FORM:FIX] - 1
ITEM
SETTING RANGE
No
.
UNIT
SCHEDULE (Enter No. optionally
.)
SLOPE
TIME
00.0 - 50.0
ms
FLASH1
TIME
00.2 - 50.0
ms
POWER
000.0 - 200.0
%
COOL1
TIME
00.0 - 50.0
ms
FLASH2
TIME
00.0 - 50.0
ms
POWER
000.0 - 200.0
%
COOL2
TIME
00.0 - 50.0
ms
FLASH3
TIME
00.0 - 50.0
ms
POWER
000.0 - 200.0
%
SLOPE
TIME
00.0 - 50.0
ms
PEAK POWER
ML-3030AS:
ML-3015AS:
1.000 - 2.700
1.000 - 1.350
kW
REPEA
T
0001 - 1000
pps
SHOT
0001 - 9999
ENERGY
HIGH
00.000 - 99.999
J
LOW
00.000 - 99.999
J