174
ML-3030AS/3015AS
2 . Troubles not Displaying Fault Code
2 . Troubles not Displaying Fault Code
States of Laser
Measures
Laser output increases though monitor displays normal value.
(When welding spot is not clean or spatter increases.)
Adjust PEAK POWER and output time. If the
laser does not improve though the setting is
adjusted, optical axis of resonator may have
been dislocated. For adjusting the axis, con-
sult us.
Laser output decreases though monitor displays normal val-
ue. (When welding is not performed or weld strength is not
enough.)