166
ML-3030AS/3015AS
1 . Maintenance Parts and Standard Intervals of Inspection/Replacement
1 . Maintenance Parts and Standard Intervals of Inspec-
tion/Replacement
The performance of maintenance parts will be gradually deteriorated while they
are used, and they may have to be repaired or replaced . Perform inspection
periodically referring to the following table .
⇒
The model numbers of maintenance parts are subject to change without notice.
For the latest parts information, contact a nearest sales office.
Part name
Model No .
Operation
interval
(standard) (*1)
Contents of
operation (*2)
Air filter
PC1178315
Every month
Clean
1 year
Replace
Lithium battery (*3)
CR 2450
3 years
Replace
P-type load switch
T3-1-102/E+SVB-SW-T0
5 years
Replace
SPS unit 1
PBA1500F-48
5 years
Repair or
Replace
SPS unit 2
PBA300F-24
5 years
Repair or
Replace
Electromagnetic contactor
SC-4-1/G coil DC24V 1b
5 years
Replace
Branch
unit
Single
AS1178501
2 years
Replace
2-powershasring
AS1178503
2-timesharing
AS1178502
Safety shutter (*4)
AS1174565
5 million times
Replace
Timesharing unit (*5)
AS1177380
1 million times
Replace
Optical
fiber (*6)
φ 0.1mm, 5m
PO1178504
2 years
Replace
φ 0.1mm, 10m
PO1178505
φ 0.2mm, 5m
PO1178506
φ 0.2mm, 10m
PO1178507
φ 0.3mm, 5m
PO1175451
φ 0.3mm, 10m
PO1175452
φ 0.4mm, 5m
PO1175453
φ 0.4mm, 10m
PO1175454
φ 0.6mm, 5m
PO1175455
φ 0.6mm, 10m
PO1175456
φ 0.8mm, 5m
PO1177722
φ 0.8mm, 10m
PO1177723
Summary of Contents for ML-3015AS
Page 21: ...Introduction Part...
Page 22: ......
Page 30: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 52: ......
Page 53: ...Operating Part...
Page 54: ......
Page 163: ...Maintenance Part...
Page 164: ......
Page 175: ...Appendixes...
Page 176: ......