4 . Commands
147
ML-3030AS/3015AS
Chapter 5 Laser W
elding by External Communication Control (RS-485 CONTROL)
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
Set Value/Monitor Value Table
⇒
The items marked * are monitor values. These values can be read out but can-
not be set.
⇒
The value in ( ) indicates the unit.
⇒
The unit of time setting depends on the setting of "RESOL" on the SCHEDULE
screen. When setting to 0.05 ms, set the values in increment of 5.
84 Schedule Settings for FIX, FLEX and CW
Data No .
Item
Data Range
01
[FORM] on the [SCHEDULE] screen
Selection of waveform setting method
0: FIX 1: FLEX 2: CW
0 – 2
02
Turning ON/OFF the graph display on the
[SCHEDULE] screen
0: OFF 1: ON
Fixed to 1
03
[PEAK POWER] on the [SCHEDULE] screen
Laser output peak value
ML-3030AS :
FIX/FLEX : 00500 – 02700 (×1W)
CW : 00050 – 00270 (×1W)
ML-3015AS :
FIX/FLEX : 00250 – 01350 (×1W)
CW : 00025 – 00135 (×1W)
04
[REPEAT] on the [SCHEDULE] screen
Pulse repetition rate
FIX/FLEX : 00001 – 01000
(Cannot be set in the CW mode.)
05
[SHOT] on the [SCHEDULE] screen
Number of consecutive shots
FIX/FLEX : 0001 – 9999
(Cannot be set in the CW mode.)
06
[HIGH] on the [MONITOR] screen
Energy monitor upper limit setting
FIX/FLEX : 000000 – 099999
(×0.1J/×0.01J)
CW : 000000 – 000999 (×1%)
07
[LOW] on the [MONITOR] screen
Energy monitor lower limit setting
FIX/FLEX : 000000 – 099999
(×0.1J/×0.01J)
CW : 000000 – 000999 (×1%)
08
Turning ON/OFF the graph display on the [MON-
ITOR] screen
0: OFF 1: ON
Fixed to 1
09
Unused
Fixed to 100
85 Schedule Settings for FIX
Data No .
Item
Data Range
01
[
SLOPE] TIME on the [SCHEDULE] screen
0000 – 5000 (×0.1ms/×0.01ms)
02
[FLASH 1] TIME on the [SCHEDULE] screen
0000 – 5000 (×0.1ms/×0.01ms)
03
[FLASH 2] TIME on the [SCHEDULE] screen
0000 – 5000 (×0.1ms/×0.01ms)
04
[FLASH 3] TIME on the [SCHEDULE] screen
0000 – 5000 (×0.1ms/×0.01ms)
05
[
SLOPE] TIME on the [SCHEDULE] screen
0000 – 5000 (×0.1ms/×0.01ms)
06
Unused
Fixed to 0000
07
[FLASH 1] POWER on the [SCHEDULE] screen
0000 – 2000 (×0.1%)
08
[FLASH 2] POWER on the [SCHEDULE] screen
0000 – 2000 (×0.1%)
Summary of Contents for ML-3015AS
Page 21: ...Introduction Part...
Page 22: ......
Page 30: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 52: ......
Page 53: ...Operating Part...
Page 54: ......
Page 163: ...Maintenance Part...
Page 164: ......
Page 175: ...Appendixes...
Page 176: ......