128
ML-3030AS/3015AS
3 . Connector Functions
E-STOP Connector (D-Sub 25 pin)
The E-STOP connector inputs and outputs an emergency stop signal for the la-
ser and inputs an external interlock signal .
⇒
Use the following product mounted on the main unit.
Socket
Case
Manufacturer
HDB-25S(05)
HDB-CTH(10)
HIROSE ELECTRIC CO., LTD.
Input Pins of E-STOP Connector
Pin No .
Description
1
Emergency stop input 1
When the section between pin No.1 and pin No.18 or the section between pin No.3 and
pin No.5 is put in an open circuit, an emergency stop is activated, the LD is turned off,
and the safety shutter is closed.
To cancel it, put all the sections between pin No.1 and pin No.18, between pin No.14
and pin No.19, between pin No.3 and pin No.5, and between pin No.6 and pin No.16 in
open circuit and put them in closed circuits. Then, input the trouble reset signal.
3
5
18
6
Emergency stop input 2
When the section between pin No.14 and pin No.19 or the section between pin No.6
and pin No.16 is put in an open circuit, an emergency stop is activated, the LD is turned
off, and the safety shutter is closed.
To cancel it, put all the sections between pin No.1 and pin No.18, between pin No.14
and pin No.19, between pin No.3 and pin No.5, and between pin No.6 and pin No.16 in
open circuit and put them in closed circuits. Then, input the trouble reset signal.
14
16
19
11
External interlock input 1
When the section between pin No.11 and pin No.24 is put in an open circuit, the safety
shutter is closed.
To cancel it, put all the section between pin No.11 and pin No.24 and the section be-
tween pin No.12 and pin No.25 in open circuits and put them in closed circuits. Then,
input the trouble reset signal.
24
12
External interlock input 2
When the section between pin No.12 and pin No.25 is put in an open circuit, the safety
shutter is closed.
To cancel it, put all the section between pin No.11 and pin No.24 and the section be-
tween pin No.12 and pin No.25 in open circuits and put them in closed circuits. Then,
input the trouble reset signal.
25
Emergency stop input 1 (in)
Emergency stop input 1 (in)
Emergency stop input 1 (in)
Emergency stop input 2 (in)
Emergency stop input 1 (out)
Emergency stop input 1 (out)
External interlock input 1 (in)
External interlock input 2 (in)
(in) Emergency stop input 2
(in) Emergency stop input 2
(in) Emergency stop input 1
(in) Emergency stop input 2
(out) Emergency stop output 2
(out) Emergency stop output 2
(in) External interlock input 1
(in) External interlock input 2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Summary of Contents for ML-3015AS
Page 21: ...Introduction Part...
Page 22: ......
Page 30: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 52: ......
Page 53: ...Operating Part...
Page 54: ......
Page 163: ...Maintenance Part...
Page 164: ......
Page 175: ...Appendixes...
Page 176: ......